SmartWire-DT In-Panel and On-Machine Wiring Solution
Gateway Modules, continued
Note
1
If contactors with a total current consumption >0.7 A are connected, a Power Feeder module EU5C-SWD-PF2 has to be used.
Description Unit
EU5C-SWD-
EIP-MODTCP
Gateway
EU5C-SWD-
PROFINET
Gateway
EU5C-SWD-DP
Gateway
EU5C-SWD-
ETHERCAT
Gateway
EU5C-SWD-CAN
Gateway
EU5C-SWD-
POWERLINK
Gateway
Supply Voltage U
Pow
Supply voltage V 24 Vdc (–15%/+20%) 24 Vdc (–15%/+20%) 24 Vdc (–15%/+20%)
Input voltage ripple %
<
5
<
5
<
5
<
5
<
5
<
5
Siemens MPI, (optional) Yes Yes Yes Yes Yes Yes
Rated current (I) A 0.7 0.7 0.7 0.7 0.7 0.7
Overload proof Yes Yes Yes Yes Yes Yes
Inrush current and duration A 12.5 A/6 ms 12.5 A/6 ms 12.5 A/6 ms 12.5 A/6 ms 12.5 A/6 ms 12.5 A/6 ms
Heat dissipation at 24 Vdc W 3.8 3.8 3.8 3.8 3.8 3.8
Potential isolation between U
Pow
and
15 V SmartWire-DT supply voltage
No No No No No No
Bridging voltage dips ms 10 10 10 10 10 10
Repetition rate s 1 1 1 1 1 1
Status indication (LED) Yes Yes Yes Yes Yes Yes
SmartWire-DT Supply Voltage
Rated operating voltage (U
e
) V 14.5 ±3% 14.5 ±3% 14.5 ±3% 14.5 ±3% 14.5 ±3% 14.5 ±3%
Max. current (I
max
)A0.7
1
0.7
1
0.7
1
0.7
1
0.7
1
0.7
1
Short-circuit proof Yes Yes Yes Yes Yes Yes
Connection Supply Voltages
Connection type Push in terminals Push in terminals Push in terminals Push in terminals Push in terminals Push in terminals
Solid mm
2
0.2–1.5 (AWG 24–16) 0.2–1.5 (AWG 24–16) 0.2–1.5 (AWG 24–16) 0.2–1.5 (AWG 24–16) 0.2–1.5 (AWG 24–16) 0.2–1.5 (AWG 24–16)
Flexible with ferrule mm
2
0.25–1.5 0.25–1.5 0.25–1.5 0.25–1.5 0.25–1.5 0.25–1.5
SmartWire-DT Network
Station type SmartWire-DT master SmartWire-DT master SmartWire-DT master SmartWire-DT master SmartWire-DT master SmartWire-DT master
Number of SmartWire-DT modes 99 99 58 58 99 99
Baud rates 125
250
125
250
125 125 125 125
Address allocation Automatic Automatic Automatic Automatic Automatic Automatic
Status indication (LED)
SmartWire-DT master Green Green Green Green Green Green
Configurations Red Red Red Red Red Red
Connections Plug, 8-pole Plug, 8-pole Plug, 8-pole Plug, 8-pole Plug, 8-pole Plug, 8-pole
Plug connectors Blade terminal
SWD4-8MF2
Blade terminal
SWD4-8MF2
Flat plug
SWD4-8MF2
Flat plug
SWD4-8MF2
Flat plug
SWD4-8MF2
Flat plug
SWD4-8MF2
Fieldbus Interface
Bus protocol Ethernet IP/Modbus TCP
slave
Ethernet IP/Modbus TCP
slave
PROFIBUS-DP PROFIBUS-DP CANopen CANopen
Baud rates 10/100 mB 10/100 mB Up to 12 mB Up to 12 mB To 1 mB To 1 mB
Address allocation Automatic Automatic Automatic Automatic Automatic Automatic
Station address 2–125 2–125 2–32 2–32
Address allocation DIP
switch/DHCP/BOOTP
selection via DIP switch
DIP
switch/DHCP/BOOTP
selection via DIP switch
DIP switch DIP switch DIP switch DIP switch
Status display fieldbus interface (LED) Link status:
yellow (10 mB),
green (100 mB) flashing
Link status:
yellow (10 mB),
green (100 mB) flashing
Two-colored red/green Two-colored red/green Two-colored red/green Two-colored red/green
Terminating resistor Switchable via plug Switchable via plug DIP switches DIP switches
Connection design for field bus 2 x RJ45
(2-channel switch)
2 x RJ45
(2-channel switch)
1 x SUB-D socket,
9-pole
1 x SUB-D socket,
9-pole
1 x SUB-D plug,
9-pole
1 x SUB-D plug,
9-pole
Potential isolation Yes Yes Yes Yes Yes Yes