9.1
Connectivity Solutions
SmartWire-DT In-Panel and On-Machine Wiring Solution
Machine Mount I/O Modules
Description Unit EU1E-SWD-2DX EU1E-SWD-2DD EU2E-SWD-4DX EU2E-SWD-4DD
General
Standards IEC/EN 61131-2, EN50178,
IEC/EN 60529
IEC/EN 61131-2, EN50178,
IEC/EN 60529
IEC/EN 61131-2, EN50178,
IEC/EN 60529
IEC/EN 61131-2, EN50178,
IEC/EN 60529
Dimensions (W x H x L) reference only mm 41 x 20 x 59 41 x 20 x 59 41 x 20 x 71 41 x 20 x 71
Weight g / oz 65 / 2.3 65 / 2.3 85 / 3.0 85 / 3.0
Form factor IP67 tee (single) IP67 tee (single) IP67 tee (single) IP67 tee (single)
Enclosure material Tee MM 6208 (black) MM 6208 (black) MM 6208 (black) MM 6208 (black)
Mounting Qty 2 mounting holes or with
bracket accessory
2 mounting holes or with
bracket accessory
2 mounting holes or with
bracket accessory
2 mounting holes or with
bracket accessory
Ambient Conditions, Mechanical
Protection type Type IP67 IP67 IP67 IP67
EN/IEC 60529 Type IP6X /IPX7 IP6X /IPX7 IP6X /IPX7 IP6X /IPX7
UL type 1111
Vibrations
Displacement 3.5 mm Hz 5–8.4 5–8.4 5–8.4 5–8.4
Acceleration 1 g Hz 8.4–150 8.4–150 8.4–150 8.4–150
Shock IEC 60068-2-27 1/2 sine 30 g/11 ms Impacts 9999
Drop to Height, mm 50 50 50 50
Drop freefall m 0.3 0.3 0.3 0.3
EMC
Overvoltage category II II II II
Pollution degree 3333
Electrostatic discharge Performance Criterion B Performance Criterion B Performance Criterion B Performance Criterion B
Air discharge (level 3) kV8888
Contact discharge (level 2)kV4444
Electromagnetic fields Performance Criterion A Performance Criterion A Performance Criterion A Performance Criterion A
80–1000 MHz V/m 10 10 10 10
1.42 G V/m3333
22.7 G V/m1111
Radio Interference suppression (SmartWire-DT)
(emission and conducted interface voltage)
EN 55011 Class A Class A Class A Class A
Burst (level 3) Performance Criterion B Performance Criterion B Performance Criterion B Performance Criterion B
Supply cables kV2222
Signal cables kV 1111
SmartWire-DT cables kV1111
Surge (level 1) Performance Criterion B Performance Criterion B Performance Criterion B Performance Criterion B
Supply cables kV 0.5 0.5 0.5 0.5
I/O cables kV1111
SmartWire-DT cables kV 1kV (not possible according
to EN61000-6-2 Table 2
1 kV (not possible according
to EN61000-6-2 Table 2
1 kV (not possible according
to EN61000-6-2 Table 2
1 kV (not possible according
to EN61000-6-2 Table 2
Radiated RFI (level 3) (150 kHz–80 MHz) Performance Criterion A Performance Criterion A Performance Criterion A Performance Criterion A
Supply cables V10101010
I/O cables V 10 10 10 10
SmartWire-DT cables V 10 10 10 10
Voltage drops and interrupts mS 10 10 10 10
Climatic Environmental Conditions
Ambient temperature °C –25 to +70 –25 to +70 –25 to +70 –25 to +70
Storage temperature °C –40 to +70 –40 to +70 –40 to +70 –40 to +70
Humidity % RH 95 at 55 °C /5–95
condensation permitted
95 at 55 °C /5–95
condensation permitted
95 at 55 °C /5–95
condensation permitted
95 at 55 °C /5–95
condensation permitted