Specification

For more information visit: www.cutler-hammer.eaton.com TD00502001E
Technical Data
Page 20 Effective: April 2002
Meter Breakers
Technical Data and Specifications
Typical Wiring Diagrams (Type CH Style House Panels)
Figure 45. Type CH Wiring Diagram 1 —
Catalog Number CG30SHL
Figure 46. Type CH Wiring Diagram 2 —
Catalog Numbers CG403242S and CG403242SH
Figure 47. Type CH Wiring Diagram 3 —
Catalog Number CG304242SHL
Figure 48. Type CH Wiring Diagram 4 —
Catalog Numbers CG40S, CG40SH and CG40SHL
Figure 49. Type CH Wiring Diagram 5 —
Catalog Number CG30S
Figure 50. Type CH Wiring Diagram 6 —
Catalog Number CG404242SHL
Figure 51. Type CH Wiring Diagram 7 —
Catalog Number CG303242S
Figure 52. Type CH Wiring Diagram 8 —
Catalog Number CG1212P400BS
Figure 53. Type CH Wiring Diagram Key
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CHB
(OPTIONAL)
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
200A MAX.
SERVICE
DISCONNECT
TYPE BW
(OPTIONAL)
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19
20
23
21
25
22
27
24
29
26
31
28
33
30
35
32
37
34
39
36
41
38
40
42
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CHB
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19 20
21 22
23 24
25 26
27
28
29 30
31 32
33 34
35 36
37 38
39
40
41 42
(OPTIONAL)
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
200A MAX.
SERVICE
DISCONNECT
TYPE BW
(OPTIONAL)
(OPTIONAL)
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CH
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
NB
LINE
FACTORY/FIELD
INSTALLED
200A MAX.
SERVICE
DISCONNECT
TYPE CSR
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19 20
21 22
23 24
25 26
27
28
29 30
31 32
33 34
35 36
37 38
39
40
41 42
(OPTIONAL)
1 2
3 4
5 6
11
9
7
12
10
8
13 14
15
16
17 18
19
20
23
21
25
22
27
24
29
26
31
28
33
30
35
32
37
34
39
36
41
38
40
42
FACTORY/FIELD
INSTALLED
100A MAX.
SERVICE
DISCONNECT
TYPE CH
A
BONDED
NEUTRAL
EQUIPMENT
GROUNDING
TERMINALS
400 AMPS
(320 AMPS
CONTINUOUS)
FACTORY
INSTALLED
200A
SERVICE
DISCONNECT
N B
LINE
(OPTIONAL)
#14-6ÿ AWG
#14-1/0ÿAWG
#6ÿ AWGÿ Ðÿ 250ÿ kcmil
#1ÿ AWGÿ Ðÿ 300ÿ kcmil