Specification
Volume 15—Solar Inverters and Electrical Balance of System CA08100018E—April 2014 eaton.com/solar V15-T1-17
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1.3
Residential Electric Vehicle Charging
Level 2 Charging Station
Catalog Number Selection
Level 2 Charging Station
Product Selection
Level 2 Charging Station
Technical Data and Specifications
Level 2 Charging Station
EVSE L2 30 H L B W
Type
EVSE = Electric Vehicle
Supply Equipment
Level
L2 = Level 2 (208/240 Vac)
Mount
W = Wall
P = Pedestal
D = Dual
Connection
H = Hardwired
C = Cord-and-plug
connected
Lighting
N = None
L = LED
Cord Management
B = Basic
A = Advanced
Amperage
16 = 16A
30 = 30A
Description
Input voltage 208/240 Vac
Input amperage 16A or 30A
Max power 3.8 kW (L216 style)
7.2 kW (L230 style)
Mount Wallmount or pedestal
Safety specifications ETL Listed to UL 2594/2231/1998
cETL Listed
Enclosure NEMA 3R
stainless steel
Quick and easy
installation
Yes
Ground fault protection Yes
Overcurrent protection Yes
Features SAE J1772 compliant
Permanent or cord-and-plug wallmount
Quick and easy installation
Build-to-order customization available
Options High-efficiency, LED site-lighting,
sub-metering
Applications/markets Single and multi-family homes,
real estate developers, builders,
government city centers, schools,
small offices
Charge time
Level 2 Charging
Station
Description Specification
Electrical Input
Voltage 208/240 Vac
Amperage 16A (L116 Style)
30A (L230 Style)
Connection Hardwired connected
Electrical Output
Power 3.8 kW (L216 Style)
7.2 kW (L230 Style)
Connector SAE J1772
Cable length 24 feet
Physical/Environmental
Weight 23 lbs
Operating temperature –30° to 50°C
Status indicators 5 LEDs: “Power/Ready”, “Connected/Charging”,
“Remotely Controlled”, “Fault” and “Service”
Push buttons Two buttons: “Override” and “Reset Fault”
Enclosure rating NEMA Type 3R—stainless steel
Safety
ETL Listed to UL 2594/2231/1998
cETL Listed
Interlocked power protection
Ground fault protection
Overcurrent protection