Product Brochure

Solar power center meter breakers
Type CH meter breakers
Catalog Number
Max. Number
of 3/4-Inch
Spaces
Max. Number
of Circuits
Main
Breaker
(A)
Bus
Rating
(A)
Max. PV
Input (A) Mounting
Service
Design Bus kAIC Enclosure
A
Combination Service Entrance Devices—EUSERC (Side-by-Side Construction)
CMBE3242PV200BF 32 42 200 225 70 Flush UG Cu 22 7
CMBE3242PV200BS 32 42 200 225 70 Surface UG Cu 22 7
CMBE4242PV200BF 42 42 200 225 70 Flush UG/OH Cu 22 12
CMBE4242PV200BS 42 42 200 225 70 Surface UG/OH Cu 22 12
CMBE4242PV200TS 42 42 200 225 70 Surface OH Cu 22 12
Combination Service Entrance Devices—Non-EUSERC—Lever Bypass (Over/Under Construction)
CMBX3242PV200TS 32 42 200 225 70 Surface UG/OH Cu 22 14
Type BR meter breakers
Catalog Number
Max. Number
of 1-Inch
Spaces
Max. Number
of Circuits
Main
Breaker
(A)
Bus
Rating
(A)
Max. PV
Input (A) Mounting
Service
Design Bus kAIC Enclosure
A
Combination Service Entrance Devices—EUSERC (Side-by-Side Construction)
MBE1224PV100BTF 12 24 100
B
125 50 Flush UG/OH Al 10 2
MBE1224PV100BTS 12 24 100
B
125 50 Surface UG/OH Al 10 2
MBE1224PV125BTF 12 24 125
B
125 25 Flush UG/OH Al 10 2
MBE1224PV125BTS 12 24 125
B
125 25 Surface UG/OH Al 10 2
MBE2040PV200BTF 20 40 200 225 70 Flush UG/OH Cu 22 18
MBE2040PV200BTS 20 40 200 225 70 Surface UG/OH Cu 22 18
MBE3042PV200BF 30 42 200 225 70 Flush UG Cu 22 7
MBE3042PV200BS 30 42 200 225 70 Surface UG Cu 22 7
MBE4040PV200BTF 40 40 200 225 70 Flush UG/OH Cu 22 12
MBE4040PV200BTS 40 40 200 225 70 Surface UG/OH Cu 22 12
Combination Service Entrance Devices—EUSERC—7-Inch-Deep Design
MBED3042PV200BF 30 42 200 225 70 Semi-flush UG Cu 22
Combination Service Entrance Devices—Non-EUSERC (Over/Under Construction)
MB2040PV200BTS 20 40 200 225 70 Surface UG/OH Cu 22
Combination Service Entrance Devices—Non-EUSERC—Lever Bypass (Over/Under Construction)
MBX2040PV200BTS 20 40 200 225 70 Surface UG/OH Cu 22
A
For box size information, refer to Electrical Sector Solutions—Volume 1: Residential and Light Commercial, Tab 1, CA08100002E.
B
Type BR main breaker factory installed. All other units Type CSR.
Solar power center loadcenters
Type CH plug-on neutral loadcenters
Catalog
Number
Max. Number
of 3/4-Inch Spaces
Max. Number
of Circuits
Main
Breaker
(A)
A
Bus
Rating
(A)
Max. PV
Input (A) Mounting Enclosure Bus kAIC
Box
Size
B
Cover
Included
CH32PVPN200 32 32 200 225 70 Combination NEMA 1 Cu 25 J Yes
CH42PVPN200 42 42 200 225 70 Combination NEMA 1 Cu 25 K Yes
CH60PVPN200 60 120
C
200 225 70 Combination NEMA 1 Cu 25 N Yes
Type BR loadcenters
Catalog
Number
Max. Number
of 1-Inch Spaces
Max. Number
of Circuits
Main
Breaker
(A)
A
Bus
Rating
(A)
Max. PV
Input (A) Mounting Enclosure Bus kAIC
Box
Size
B
Cover
Included
BR2040PV200 20 40 200 225 70 Combination NEMA 1 Cu 25 D1 Yes
BR2040PV200R
B
20 40 200 225 70 Surface NEMA 3R Cu 25 D1R Yes
BR4242PV200 42 42 200 225 70 Combination NEMA 1 Cu 25 L2 Yes
BR4242PV200R
B
42 42 200 225 70 Surface NEMA 3R Cu 25 L2R Yes
A
Type CSR main breaker factory installed.
B
Rainproof panels are furnished with hub closure plates. For rainproof hubs or box size information, refer to Electrical Sector Solutions—Volume 1: Residential and Light Commercial, Tab 1, CA08100002E.
C
Requires the use of Type CHNT breakers.
For additional information about
loadcenters, meter breakers and
accessories, see
Volume 1: Residential and Light
Commercial, CA08100002E, Tab 1