Datasheet

DATASHEET - MCS4
Pressure switch, 1W, 7bar, 0.2bar
Part no. MCS4
Catalog No. 019711
Eaton Catalog No. MCS4
EL-Nummer
(Norway)
0004356105
Delivery program
Note on use This product complies with Low-Voltage Directive 2014/35/EC and EMC Directive
2014/30/EC and meets the requirements in EN 60947-5-1. This product does not
meet the rail industry's standard requirements. Accordingly, the user must review it
separately for the specific application at hand.
Product range Pressure switches with auxiliary contacts
Degree of Protection IP65
Contacts 1 changeover contact
Cut-in pressure and cut-out pressure:
separate stepless adjustment.
All the intersection points within the diagram area can be set.
Min. switching differential: 0.15 bar
Example:
Cut-out pressure 3.3 bar
Cut-in pressure 2.2 bar
Variable switching differential
Max. operating pressure bar 7
Notes
Features:
Pressure pipe flange R¼”
If required: pressure pipe flange R½”
IP65 in conjunction with V-M20 cable gland
1 Insulated protective conductor terminal
2 cable entry knockouts for M20
Neoprene membrane, resistant to aging, air, engine oil, and water min. -25 °C, max. +80 °C
Cut-in and cut-out pressures are factory-preset as specified with type suffix: →#203948
R¼” corresponds to G¼
R½” corresponds to G½ according to ISO 228-1
Auxiliary contact to IEC/EN 60947-1
Technical data
General
Standards IEC/EN 60947-5-1
Test pressure bar 32
Rupturing pressure bar 90
Operating frequency Operations/h ≦ 1500
02/07/2019 Eaton 019711 ED2019 V52.0 EN 1 / 5

Summary of content (5 pages)