Instructions / Assembly

First Location Second Location
3 traveler wires are required
DIAGRAM 2A: SWITCH IN LOCATION WITH HOT WIRE
3-Way Switch
OS310U or VS310U Sensor
Hot
Black
Hot
Black
Black
Ground
Bare
Green
3-Way
Blue
Neutral
NeutralNeutral
Neutral
White
White
White
Light Fixture
Black Traveler
Red Traveler
White Traveler
Red
Output
CCaattaalloogg ## OOSS331100UU AAuuttoo OOnn SSeennssoorr ((SSiinnggllee OOuuttppuutt)) CCaattaalloogg ## VVSS331100UU MMaannuuaall OOnn SSeennssoorr ((SSiinnggllee OOuuttppuutt))
S
PECIFICATIONS
• Single Pole and 3-Way
• 8.3A (1000W), 120V AC 60 Hz.
For Incandescent, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Fluorescent,
C
ompact Fluorescent, LED, Motors up to 1/6 HP
• Includes Selectable and Dimmable Nightlight
NOTE - A Neutral Connection is required in the wallbox where the sensor will be installed
D
ESCRIPTION
• This Sensor Wall Switch can replace a standard wall switch in any of the following applications:
• Single location – one Single Pole switch.
Two location – one location is the sensor and the other location is a standard 3-way switch
• Two location – replace both 3-Way switches with sensors.
• The OS310U turns on automatically when a person enters the room.
The VS310U requires manual activation to turn on the lights.
• Both OS310U and VS310U will automatically turn off lights after a selectable time delay.
• OS310U incorporates the ability to detect when rooms are only occupied very briefly and shortens the time
d
elay in order to save energy.
OS310U includes a light level adjustment for daylight to prevent motion from turning on the lights.
• A green LED indicates the load status and provides a momentary flash to indicate motion.
OPERATION INSTRUCTIONS
A
uto ON Sensor – OS310U (Occupancy Mode):
• OS310U will turn on lights automatically when a person enters the room
Lights will turn off automatically when no motion is detected after a selectable time delay.
• The selectable time delays are 5 seconds (Test Mode), 5 minutes (factory default), 15 minutes and 30 minutes.
Manual ON Sensor – VS310U (Vacancy Mode):
The VS310U must be turned on manually with the ON/OFF button.
Lights will turn off automatically when no motion is detected after a selectable time delay.
• The selectable time delays are 5 seconds (Test Mode), 5 minutes, 15 minutes and 30 minutes (factory default).
• When the lights have turned off due to a lack of motion, the lights will turn ON automatically if motion is
d
etected within 10 seconds.
Night Light
• Press the Night Light lens momentarily to turn the Night Light ON or OFF.
• When the Night Light is ON, press and hold the Night Light lens to dim the Night Light to the desired brightness.
Release when the desired brightness level is reached. Press and hold again to brighten.
• The OS310U can also operate as a Manual ON sensor when the Night Lite is ON. Refer to OS310U Special
Modes for additional explanation.
OS310U SPECIAL MODES
Reverse Mode: The reverse mode is used when the lights must stay OFF in a room while motion is detected. If the lights are ON, a double tap of the ON/OFF button will turn off the lights
and put the device into the Reverse Mode. This allows the lights to stay OFF as long as motion is detected. After the time delay is finished the sensor operation goes back to normal.
Manual ON Only mode: This mode may be selected to prevent motion from automatically turning on the lights. Press and hold the ON/OFF button for 5 seconds until the indicator LED
blinks. Release the button while the LED is blinking. Repeat this procedure to restore normal operation. While the OS310U is in the manual ON mode, it will behave like a VS310U.
Override Mode: Turns off all motion sensing and allows the device to be used as a regular ON/OFF switch or in the unlikely event of a failure of the motion sensor. Press and
hold the ON/OFF button for 10 seconds until the indicator LED blinks for the second time (the LED will also blink at the 5 second point). Release the button while the LED is
blinking. Repeat this procedure to restore normal operation. This mode also can be used on VS310U.
Automatic On Mode with Night Light On: When in the auto ON mode, when the Night Light is turned on, the sensor will operate in the manual ON mode. This feature can be enabled by
pressing and holding the Night Light button for 5 seconds while the Night Light is OFF. The Night Light will blink after 5 seconds. Release the button while the Night Light is blinking.
Repeat this procedure to restore normal operation.
INSTALLATION INSTRUCTIONS
WARNING:
Turn OFF circuit breaker or remove fuse(s) and verify that power is off before wiring.
• Never wire any electrical device with power turned on. Wiring the device with the power on may cause permanent damage to
the device and void the warranty.
• If you are unsure about any part of these instructions, or if the wiring does not match the descriptions given, you should call a
qualified electrician.
CAUTION:
• Must be installed and used in accordance with all applicable electrical codes.
• If a bare copper or green ground connection is not available in the wallbox, contact a qualified electrician for installation.
Do not install without proper ground connections.
• Do not exceed maximum device ratings.
• For use ONLY with permanently installed fixtures of these types:
Incandescent/Halogen, Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Fluorescent, Compact Fluorescent, LED.
• May also be used with motors up to 1/6 HP
• To avoid overheating and possible damage to other equipment, do not use to control receptacles.
• Use only #14 or #12 copper wire with these devices.
Installing OS310U & VS310U
Refer to the wiring diagrams and install the sensor according to these directions.
You must verify that a neutral wire is available in the wallbox.
For single pole applications, wire the sensor switch according to wiring diagram #1 using the wire nuts provided.
1. The sensor black wire will connect to the hot wire (black) in the wallbox.
2. The sensor red wire will connect to the wire which goes to the light fixture.
3. The sensor white wire will connect to the neutral wire (white) in the wallbox.
4. The sensor blue wire is not used and should be capped off with a wire nut.
5. The sensor green wire will connect to the ground wire in the wallbox.
6. Install the sensor loosely using the mounting screws provided.
7. Apply power temporarily and verify that the sensor works by pushing the ON/OFF button to verify the lights turn on
and off. If the lights do not work, then turn off the power and swap the connections on the sensor black and red wires
8. Apply power again and verify that the sensor works by pushing the ON/OFF button to verify the lights turn on and off.
9. Turn power OFF and go to COMPLETING THE INSTALLATION.
For 3-way applications, wire the sensor switch according to wiring diagram #2A or 2B using the wire
nuts provided. The sensor may be placed at either end of the 3-way circuit.
1. Remove the existing switch in the location where the sensor will be installed.
a. The sensor black wire will connect to either one of the black wires in the wallbox.
b. The sensor red wire will connect to the other black wire in the wall box.
c. The sensor white wire will connect to the neutral wire (white) in the wallbox.
O
CCSWITCH-PTA (REV. A)
ENGLISH
IINN UU..SS..AA..::
Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293
DIAGRAM 1: SENSOR IN ONE LOCATION
OS310U or VS310U Sensor
Light Fixture
White
Neutral
White
Neutral
White
Neutral
Ground
Bare Green
3-Way
Blue
Black
Hot
Black
Hot
Black
Output
Red
0
1
5’
MAJOR MOTION
1000 SQ. FT.
36’
0
COVERAGE PATTERN
MINOR MOTION
300 SQ. FT.
8
15’
8’
1
5’