Cut Sheet

16
Technical Data TD01701001E
Effective March 2017
UL low-voltage busway
Pow-R-Way III
EATON www.eaton.com
Physical data (continued)
Traditional indoor and outdoor elbows (Figure 17)
Elbows are used to make 90° changes in the direction of busway
runs. The four types that are available are forward, rearward, upward,
and downward. See minimum leg lengths listed for each type in
Table 19 and Table 20.
ote:N All dimensions are to the centerline of the Pow-R-Bridge.
Figure 17. Traditional elbows
Corner joint elbows (Figure 18)
The Pow-R-Way III corner joint elbow can be installed in areas where
a traditional 90° turn could never have been accomplished before.
Pow-R-Way III corner joint elbows can solve any serious pathway
problem and contribute to successful layouts with minimal space
requirements. The corner joint elbow is UL Listed for indoor
applications only and is also certified for seismic withstand
capability to worst-case, Zone 4 levels.
ote:N All dimensions are to the centerline of the corner joint connection.
Figure 18. Corner joint elbows (for indoor applications only)
Table 19. Forward and rearward elbows
UL 857 ampere rating Dimensions in inches (mm)
Cu Al Minimum leg lengths X
225 225 13.00 (330.2)
400 400 13.00 (330.2)
600 600 13.00 (330.2)
800 13.00 (330.2)
1000 13.00 (330.2)
1200 800 13.50 (342.9)
1350 1000 13.50 (342.9)
1600 1200 14.00 (355.6)
2000 1350 14.50 (368.3)
1600 15.00 (381.0)
2500 2000 16.00 (406.4)
3200 18.50 (469.9)
4000 2500 19.50 (495.3)
3200 20.50 (520.7)
5000 4000 22.50 (571.5)
Table 20. Upward and downward elbows
UL 857 ampere rating
Dimensions in inches (mm)
Minimum leg lengths X
Cu Al Upward Downward
225 225 10.00 (254.0) 13.00 (330.2)
400 400 10.00 (254.0) 13.00 (330.2)
600 600 10.00 (254.0) 13.00 (330.2)
800 10.00 (254.0) 13.00 (330.2)
1000 10.00 (254.0) 13.00 (330.2)
1200 800 10.00 (254.0) 13.00 (330.2)
1350 1000 10.00 (254.0) 13.00 (330.2)
1600 1200 10.00 (254.0) 13.00 (330.2)
2000 1350 10.00 (254.0) 13.00 (330.2)
1600 10.00 (254.0) 13.00 (330.2)
2500 2000 10.00 (254.0) 13.00 (330.2)
3200 12.00 (304.8) 13.00 (330.2)
4000 2500 12.00 (304.8) 13.00 (330.2)
3200 12.00 (304.8) 13.00 (330.2)
5000 4000 12.00 (304.8) 13.00 (330.2)
Table 21. Forward/rearward corner joints
UL 857 ampere rating Dimensions in inches (mm)
Cu Al X Y
225 225 0.94 (23.9) 5.38 (136.7)
400 400 0.94 (23.9) 5.38 (136.7)
600 600 0.94 (23.9) 5.38 (136.7)
800 0.94 (23.9) 5.38 (136.7)
1000 1.25 (31.8) 5.69 (144.5)
1200 800 1.50 (38.1) 5.94 (150.9)
1350 1000 1.75 (44.5) 6.19 (157.2)
1600 1200 2.25 (57.2) 6.69 (169.9)
2000 1350 2.88 (73.2) 7.31 (185.7)
1600 3.25 (82.6) 7.70 (195.6)
2500 2000 4.12 (104.7) 8.57 (217.7)
3200 6.64 (168.7) 11.07 (281.2)
4000 2500 7.89 (200.4) 12.32 (312.9)
3200 8.65 (219.7) 13.08 (332.2)
5000 4000 10.42 (264.7) 14.85 (377.2)
X
C
L
C
C
C
L
C
C
X
F
o
rw
a
r
d
D
o
wnw
a
r
d
X
X
U
p
war
d
X
X
R
ea
rw
a
r
d
C
L
C
C
X
C
L
C
C
C
L
C
C
C
L
C
C
C
L
C
C
C
L
C
C
C
L
C
C
C
C
C
L
C
C
C
L
C
C
C
L
C
C
X
C
L
C
C
U
p
war
d
X
C
L
C
C
Y
F
o
rw
a
r
d
C
L
C
C
C
L
C
C
C
L
C
C
X
C
L
C
C
Y
R
ea
rw
a
r
d
C
L
C
C
C
L
C
C
C
L
C
C
C
L
C
C
Y
D
o
wnw
a
r
d
C
L
C
C
C
L
C
C
C
L
C
C
C
L
C
C
Y
C
C
L
L
C
C
C
C
L
C
C
C
L
C
C
X