Physical data (continued)
Center cable tap box (Figure 28)
Center cable tap boxes are used to center feed a run of busway
with cable and conduit or where loads served by the busway are
connected without the need for overcurrent protection. For indoor
applications, the “T” side, side opposite “T,” and the end panel
are removable for access to the lugs. For outdoor applications,
these panels are gasketed to prevent moisture from entering.
In addition, the outdoor center cable tap boxes are provided with
removable gasketed access panels located on the front and back
for more accessibility to the lugs.
ote:N All dimensions are to the centerline of the Pow-R-Bridge.
Table 36. Center tap box details—dimension C
Dimension C in inches (mm)
Copper
225–1350 A 1600–2000 A 2500 A 3200 A 4000–5000 A
3.63 (92.2) 4.75 (120.7) 6.00 (152.4) 10.75 (273.1) 12.25 (311.2)
Aluminum
225–1000 A 1200–1350 A 160–2000 A 2500–3200 A 4000 A
3.63 (92.2) 4.75 (120.7) 6.00 (152.4) 10.75 (273.1) 12.25 (311.2)
Figure 28. Center cable tap box
a
Dimension D: For mechanical lugs = 21.34 inches (542.0 mm).
For compression lugs = 19.25 inches (489.0 mm).
b
200% neutral.
Table 37. Center tap box details—dimensions A and B
Copper Aluminum
Quantity of mechanical terminals, range—one #4 (20 mm
2
)—
600 kcmil (300 mm
2
), two 1/0 (50 mm
2
)—250 kcmil (120 mm
2
)
a
UL 857
ampere
rating
Dimensions in inches (mm) UL 857
ampere
rating
Dimensions in inches (mm) Copper Aluminum
A
b
B
b
A
b
B
b
G
c
P
d
N
e
G
c
P
d
N
e
225 16.50 (419.1) 40.00 (1016.0) 225 16.50 (419.1) 40.00 (1016.0) 1 2 4 1 2 4
400 16.50 (419.1) 40.00 (1016.0) 400 16.50 (419.1) 40.00 (1016.0) 1 2 4 1 2 4
600 16.50 (419.1) 40.00 (1016.0) 600 16.50 (419.1) 40.00 (1016.0) 1 2 4
800 16.50 (419.1) 40.00 (1016.0) 16.50 (419.1) 40.00 (1016.0) 2 3 5 1 2 4
1000 16.50 (419.1) 40.00 (1016.0) 16.50 (419.1) 40.00 (1016.0) 2 3 6
1200 16.50 (419.1) 40.00 (1016.0) 800 16.50 (419.1) 40.00 (1016.0) 2 4 8 2 3 5
1350 16.50 (419.1) 40.00 (1016.0) 1000 16.50 (419.1) 40.00 (1016.0) 2 4 8 2 3 6
1600 20.50 (520.7) 42.50 (1079.5) 1200 20.50 (520.7) 42.50 (1079.5) 3 5 9 2 4 8
2000 20.50 (520.7) 42.50 (1079.5) 1350 20.50 (520.7) 42.50 (1079.5) 3 6 12 2 4 8
1600 24.50 (622.3) 45.00 (1143.0) 3 5 9
2500 24.50 (622.3) 45.00 (1143.0) 2000 24.50 (622.3) 45.00 (1143.0) 4 8 16 3 6 12
3200 30.38 (774.5) 58.00 (1473.2) 5 9 18
4000 45.00 (1143.0) 60.50 (1536.7) 2500 30.38 (771.7) 58.00 (1473.0) 6 12 24 4 8 16
3200 30.38 (771.7) 58.00 (1473.0) 5 9 18
5000 45.00 (1143.0) 60.50 (1536.7) 4000 45.00 (1143.0) 60.50 (1536.7) 7 15 30 6 12 24
a
For compression lugs, factory provides provisions only.
b
All dimensions shown in Figure 28 remain constant regardless of system wiring configuration.
c
Denotes quantity of terminals per ground bus.
d
Denotes quantity of terminals per phase and 100% neutral bus.
e
Denotes quantity of terminals per 200% neutral bus option.