Datasheet

Rev 1 Page 1 of 3
Eaton 9130 700-6000VA Tower UPS Technical Specification
CONSTRUCTION
Model
PW9130G700T
-XL
PW9130G1000T
-XL
PW9130G1500T
-XL
PW9130G2000T
-XL
PW9130G3000T
-XL
PW9130G6000T
-XL
Rating 700VA/630W 1000VA/900W 1500VA/1350W 2000VA/1800W 3000VA/2700W 6000VA/5400W
Technology VFI-SS-111, on-line double conversion with power factor correction
UPS Dimensions:
W x D* x H (mm)
160x355x250** 160x383x250** 160x435x250** 214x410x345** 214x410x345** 242x542x575
*Allow 150mm rear clearance for connections & air flow **Height includes rubber feet
Colour Black, RAL9005 (PPC-18)
Weight (kg) 12.2 14.5 19.0 34.5 34.5 75.5
ENVIRONMENTAL & SAFETY
Ambient storage temperature -20˚C to +40˚C with batteries and -25˚C to +55˚C without batteries
Ambient service temperature
Power electronics part: +0 to +40C, Battery part: +5 to 25C without reducing battery life
Maximum service altitude 1000m above sea level.
Relative humidity 5 to 90%, no condensation allowed
Degree of protection IP20 (EN60529)
Acoustic Noise <52dBA (700-3000VA), <55dBA (6000VA) Normal mode, typical load and Battery mode
Surge Suppression
EN 61000-2-2, EN 61000-4-2 Level 3
EN 61000-4-3, Level 2 (6kVA = Level 3)
EN 61000-4-4, Level 2 (also on signal ports) (6kVA = Level 3)
EN 61000-4-5, Level 3 Criteria A (IEEE C62.41 6 KV)
EN 61000-4-6, Level 2 (6kVA = Level 3)
EN 61000-4-8, Level 2 (6kVA = Level 4), EN 61000-4-11
Safety Markings CE, GS
Electromagnetic Compatibility EN 620402 Emissions, category C1; Immunity, category C2
Agency Markings CE, CTick
POWER CONNECTIONS
Input C14 10 Amp C14 10 Amp C14 10 Amp C14 10 Amp C20 16Amp
Hardwired,
10mm
2
Max
Output (6) C13 10A (6) C13 10A (6) C13 10A
(8) C13 10A,
(1) C19 16A
(8) C13 10A,
(1) C19 16A
Hardwired,
10mm
2
Max
USER INTERFACE
Display Graphical LCD with blue backlight, 4x LEDs for notice and alarm
Communication Ports
1 x USB (HID), 9600 bps, 1x RS232 (DB9, with 2 opto-coupled relay outputs), 1200-9600 bps,
1 x Minislot Communication Card Slot (Empty)
Signal Inputs
(4) programmable signal inputs (one RS-232 input, two connectivity card signal inputs, and one Emergency
Power Off input) for indicating building alarms or other use
Relay Port (1) three-pole connector with (1) contact closure (Voltage Free Contact)
Output Relay Specifications 60VDC/2A Max, 30VAC/1A Max
Optional Minislot cards; Web/SNMP, Modbus, Relay
ELECTRICAL CHARACTERISTICS – INPUT
Number of Input Phases 1 Phase (Separate Rectifier and Bypass inputs available on 6kVA)
Rated input voltage and
voltage tolerance
Rectifier : 230Vac nominal (200, 208, 220, 240V Selectable)
700-1500VA Tolerance: 120/140/160-276V (33%/66%/100% 0.7pf Load)
180-276V, (-22%, +20% at 0.8pf Load)
190-276V, (-17%, +20% at 0.9pf Load)
2000-3000VA Tolerance: 140/160/180-276V (33%/66%/100% 0.7pf Load)
190-276V, (-17%, +20% at 0.8pf Load)
200-276V, (-13%, +20% at 0.9pf Load)
6000VA Tolerance: 120/140/160/180-276V (25%/50%/75%//100% 0.9pf Load)
Bypass tolerance: 196-253V (-15%, +10% of nominal)
Operating Frequency 50 or 60Hz; Tolerance 40-70Hz
Input current distortion 700-3000VA: <8% THDi. 6000VA: 5% THDi (Linear load condition at rated input current)
Input power factor 0.99pf
Inrush Current 700-3000VA: <45A (peak) decaying exponentially within 30 ms. 6000VA: 150A <1ms
Rated Input Current @ 230V 3.0A 4.3A 7.2A 8.7A 13.0A 28.6A
Dedicated Supply CB Rating 6A 6A 10A 10A 16A 40A