Installation Guide

SPECIFICATIONS:
• For dimmable LED/CFL, Incandescent (INC), Magnetic Low Voltage (MLV), Electronic Low Voltage (ELV), Halogen or dimmable uorescent light xtures.
• CFL/LED - 300W
• Incandescent, Electronic Low Voltage, and Halogen - 600W
• Fluorescent - 600W
• Magnetic Low Voltage - 600VA
• Multigang applications allowed at above ratings.
WARNINGS AND CAUTIONS:
Turn circuit breaker to OFF position or remove fuse(s) and test that power is off before installation process. Never wire any electrical device with power turned on. Wiring dimmer HOT may cause permanent damage
to this device and other equipment and void warranty.
• Must be installed and used in accordance with all national and local electrical codes.
• To reduce the risk of overheating and possible damage to this device or other equipment, do not install to control a receptacle, motor-operated appliance, or a transformer-supplied appliance.
• Use with permanently installed fixtures, and listed 120V/AC dimmable lamp types.
• Mixing CFL and LED lamps on the same dimming circuit may result in less than optimal lighting performance.
• Only one dimmer can be used in a 3-way circuit. The switch on the other end will turn on at the brightness level selected at the dimmer.
• Do not exceed maximum rating of dimmer as indicated on the device.
• For new installations, install a test switch before installing the dimmer, to verify proper lighting circuit operation.
• If a bare copper or green ground connection is not available in the wallbox, contact a licensed electrician for installation.
• Use only #14 or #12 copper wire rated for at least 75º C with these devices. DO NOT USE WITH ALUMINUM WIRE.
• It is normal for the dimmer to feel warm during operation.
Tools needed for Installation:
• Screwdriver (Slotted/Phillips) • Pliers • Electrical tape • Cutters
• Determine what type of installation it is and follow the corresponding installation instructions below.
Single-pole installation — controls light from one location.
3-way installation — controls light from two locations.
• Turn off power. Remove wallplate.
SINGLE-POLE INSTALLATION:
1. Disconnect the existing switch, and connect dimmer as per Figure 1 — Single-Pole Wiring Diagram.
2. Connect one of the wires of the switch to the Black screw.
3. Connect the other wire from the switch to one of the Yellow screws. NOTE: One of the Yellow screws is covered by a white label, and is not required for a single-pole installation.
4. Connect the ground wire to the Green screw.
5. Insert the dimmer switch into the electrical box and attach with mounting screws provided.
NOTE: Make sure the word “TOP” is facing up on the dimmer as shown in Figure 1.
3-WAY INSTALLATION:
NOTE: One dimmer can be installed in either switch location, however, you cannot put a dimmer in both locations.
1. Select the 3-way switch to be replaced by the dimmer. This will typically be the location that you would normally want to control the dim level.
2. Tag the common wire. The wire connected to the Common terminal is identified by a marking indicating “BK”, or the screw color is Black, and is different than the other two screws.
3. Disconnect the 3-way switch that will be replaced by the dimmer.
4. Connect the dimmer as show in Figure 2 — 3-Way Wiring Diagram.
5. Connect the tagged common wire to the Black screw on the dimmer.
6. Connect one of the wires from the switch to one of the two Yellow screws and connect the other wire from the switch to the other Yellow screw.
7. Connect the Ground wire to the Green screw.
8. Insert the dimmer switch into the electrical box and attach with mounting screws provided.
NOTE: Make sure the word “TOP” is facing up on the dimmer as shown in Figure 2.
MINIMUM DIMMING LEVEL:
• A complete list of approved dimmable CFL and LED lamps is provided with this dimmer. The factory setting for the dimming level allows the dimmer to be used with a wide range of CFL and LED lamps. Some CFL and
LED lamps can be dimmed lower than the dimmer’s default factory setting. It is recommended to install the dimmer and check the performance of lamps at default factory setting. To optimize the lower end dimming
range for a particular CFL/LED lamp, see DIMMING LEVEL ADJUSTMENT section below.
NOTE: It is normal for the lights to momentarily turn ON at full brightness when power up to ensure all lights start properly at low dim levels.
DIMMING LEVEL ADJUSTMENT:
1. Do not install the wallplate. Restore power by turning ON the circuit breaker or reinstalling the fuse. Turn ON the dimmer and lower the dimmer slider to minimum (the bottom of the travel).
2. Rotate the dimming level adjustment thumbwheel DOWN until the lowest stable light level is achieved. (See Fig. 3)
3. If the light flickers, rotate the thumbwheel UP to achieve a stable light output.
4. Turn the dimmer off for 30 seconds, then back on to verify if the lamp turns ON at desired setting. If lamp does not turn ON, rotate the thumbwheel UP and repeat this step. After dimming level adjustment is completed,
install the wallplate.
NOTE: All CFL and LED lamps have different dimming range and vary with bulb type, manufacturer and may not achieve the same lower dimming level as incandescent or halogen lamps. It is also noted that unlike
incandescent lights, there is no change in the color of light when CFL or LED lamps are dimmed. There is a change only in the light output level when dimmed.
TROUBLESHOOTING
If you have a problem with your dimmer, first follow this guide. If the problem persists, call the customer service hotline at 1-866-853-4293 between 8 A.M. and 6 P.M. EST weekdays.
ENGLISH IN U.S.A.: Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293
SAL06P - ALL LOAD DIMMER, SINGLE POLE/3-WAY - 120V/AC, 60 Hz - 300W DIMMABLE LED/CFL - 600W INC/DIMMABLE ELV/HALOGEN -
600W DIMMABLE FLUORESCENT - 600VA MLV - For use with listed LED and CFL lamps
SAL06B-PTA (REV. A)
Black/Noir/Negro
Neutral/Neutre/
Neutro
YL
Line/Ligne/Linea
120V AC - 60 Hz
White/Blanc/Blanco
Hot/Phase/Fase
Load/Chargement/
Carga
BK
FIGURE 1: SINGLE POLE WIRING DIAGRAM
FIGURE 1: SCHÉMA DE CÂBLAGE DE UNIPOLAIRE
FIGURA 1: DIAGRAMA DE CABLEADO UNIPOLAR
TOP
Green or Bare/Vert ou nu/Verde o desnudo
Slider
Glissière
Deslizador
Black Thumbwheel
Noir Molette
Negro Ruedecilla
BK
YL
YL
YL
Line/Ligne/Linea
120V AC - 60 Hz
Neutral/Neutre/Neutro
White/Blanc/Blanco
Black/Noir/Negro
Hot/Phase/Fase
BK
YL
Load/Chargement/
Carga
Travellers
Navettes
Cursor
GRADATEUR
REDUCTOR
INTERRUPTEUR 3-VOIES
INTERRUPTOR 3-VIAS
Tag/Etiquette/Marca
FIGURE 2: 3-WAY WIRING DIAGRAM
FIGURE 2: SCHÉMA DE CÂBLAGE DE 3-VOIES
FIGURA 2: DIAGRAMA DE CABLEADO DE 3-VIAS
3-WAY
SWITCH
DIMMER
TOP
Green or Bare/Vert ou nu/Verde o desnudo
Slider
Glissière
Deslizador
Black Thumbwheel
Noir Molette
Negro Ruedecilla
FIGURE 3: DIMMING LEVEL ADJUSTMENT
FIGURE 3: RÉGLAGE DU NIVEAU D’ATTÉNUATION
FIGURA 3: AJUSTE DEL NIVEL DE ATENUACIÓN
SAL06P
UP/HAUT/HACIA ARRIBA
DOWN/BAS/HACIA ABAJO
MINIMUM DIMMING LEVEL ADJUSTMENT
RÉGLAGE DU NIVEAU D’ATTÉNUATION MINIMUM
AJUSTE DEL NIVEL DE ATENUACIÓN MÍNIMO
Symptoms
Possible Solution
If the light does not turn ON 1. Check to see if circuit breaker or fuse(s) has tripped.
2. Check to see if lamp is burned out.
If lights are flickering 1. Check if lamp has a bad connection.
2. Check if wires are not secured firmly under terminal screws of dimmer and/or 3-way switch (if installed).
Lights flicker or turn OFF at low dim level setting 1. Dim level adjustment set too low. Rotate the dimmer level thumbwheel UP.
Lights momentarily bright at turn ON This is a normal feature that ensures all lights start properly at low dim levels.
COOPER WIRING DEVICES LIMITED 2 YEAR WARRANTY
Cooper Wiring Devices (CWD) warrants its Smart Dimmer System to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS TWO (2) YEAR LIMITED WARRANTY IS IN LIEU OF ALL OTHER
WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS IN DURATION IN EXCESS OF TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER
PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF CWD HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF CWD UNDER THIS WARRANTY.
To obtain warranty service for any properly installed CWD Smart Dimmer System that proves defective in normal use send the defective Smart Dimmer System prepaid and insured to Quality Control Dept., Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in
Canada: Cooper Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. CWD will repair or replace the defective unit, at its option. CWD will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse,
abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to CWD. CWD SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE SMART DIMMER SYSTEM, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL,
INCIDENTAL, CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE SMART DIMMER SYSTEM OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTY ON THIS PRODUCT.
THE EXCLUSIVE REMEDY FOR BREACH OF THE LIMITED WARRANTY CONTAINED HEREIN IS THE REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT AT CWD’S OPTION. IMPLIED WARRANTIES (IF ANY) INCLUDING, BUT NOT LIMITED TO IMPLIED WARRANTIES OF
FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABIITY, ARE LIMITED IN DURATION TO A PERIOD ENDING TWO YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. IN NO CASE SHALL CWD’S LIABILITY UNDER ANY OTHER REMEDY PRESCRIBED BY LAW
EXCEED THE PURCHASE PRICE. Some states do not allow the exclusion or limitation of incidental or consequential damages or allow disclaimers or modifications of or limitations on how long an implied warranty lasts, so the above limitations may not apply to you. Some Canadian
provinces do not allow exclusion or variance of implied warranties so that some or all of the above limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state and province to province.
Read enclosed instructions carefully. If you have any questions concerning use or care of this product, please write: Consumer Service Division, Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269.

Summary of content (2 pages)