Datasheet

02/08/2017 171303 - HPL-ED2017 V29.0 EN 1 / 3
Base�module;for�vertical�mounting�on�one�sides
Part�no. SL4-PIB-FW
Article�no. 171303
Catalog�No. SL4-PIB-FW
Delivery�program
Product range SL signal towers
Basic function Base module
Connection technique Push in terminals
Mounting type for vertical mounting
Fitted with One-sided base with bracket
including cover
Number of modules max. 5 modules
Colour
black
For use with SL4-L-…
SL4-BL-…
SL4-FL-…
SL4-AP-...
Connection to SmartWire-DT no
Technical�data
General
Standards IEC/EN 60947-5-1
Climatic proofing Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60069-2-30
Mounting position for vertical mounting
Mechanical shock resistance g > 15
according to IEC 60068-2-27
Shock duration 11 ms
Sinusoidal
IEC degree of protection IP66
IEC/EN 60529
Protection type UL Type 4, 4X, 13
Cap colour
black
Ambient temperature °C -30 - +60
Number of signal elements Max. 5 with standard base
Max. 10 with base for mounting on both sides
Terminal capacity
Solid or flexible conductor
mm
2
0.2 - 1.5
Solid or flexible conductor, with ferrule
mm
2
0,25 - 1,5
Flexible with ferrule with plastic collar
mm
2
0.25 - 0.75
AWG 24 - AWG 16
Contacts
Rated impulse withstand voltage U
imp
V AC 4000
Rated insulation voltage U
i
V 250
Overvoltage category/pollution degree III/3
modules
Voltage levels 24 V AC/DC ± 10 %
110/120 V AC ± 10 %
230/240 V AC ± 10 %