Datasheet

DATASHEET - STO-SW
Rod operation
Part no. STO-SW
Catalog No. 069608
Eaton Catalog No. CTX-STO-SWQ
EL-Nummer
(Norway)
0004356153
Delivery program
Product range Accessories
Basic function Rod operation kit
Equipment supplied: 1 bracket
3 Clamp rings
1 Operating rod (insulating material, 120 cm)
2 Hexagon nut (insulating material)
Notes
Pumping full: Pumping dry:
Pivot point on left (state of delivery) Fulcrum right
Case 1 Case 2
The actuation mechanism can either be connected to the float switch's actuation lever (configuration 1) or to the float
(configuration 2). In configuration 1, the float drives the rod and the actuation lever. In configuration 2, the float and the rod drive
the actuation lever. The latter configuration should especially be used in applications with sewage pumps.
Design verification as per IEC/EN 61439
Technical data for design verification
Operating ambient temperature min. °C -25
Operating ambient temperature max. °C 70
Technical data ETIM 7.0
Low-voltage industrial components (EG000017) / Accessories for control circuit devices (EC002024)
Type of electrical accessory Other
Type of mechanical accessory Other
02/07/2019 Eaton 069608 ED2019 V52.0 EN 1 / 2