Eaton.com/epdu Eaton ePDU Product Catalog Switch N to Eaton.
eaton corporation Enclosure Power Distribution Units
Product line overview ................................................................................................................................................................................... 4 Choosing ePDU technologies ...................................................................................................................................................................... 5 Understanding ePDU technologies ................................................................................
Product line overview Product line overview Broad product portfolio Eaton® offers the largest selection of rack mounted power distribution units available on the market, we call these Eaton ePDU® units. Our complete suite of products is designed specifically to help you meet rapidly escalating requirements. High density power solutions Eaton offers a number of ePDUs to meet your high power density needs.
Eaton ePDU product search wizard makes it easy! On eaton.com/epdu, Eaton’s product search wizard is a simple interface that allows you to search over 1,000 products for the perfect solution. You can explore features, benefits and learn basic fundamentals of ePDUs, as well as interact with live demos.
Understanding ePDU technologies Understanding ePDU technologies Eaton’s ePDU technologies satisfy the demand of every data center. Eaton ePDUs offer single and dual chassis, five technology options, the broadest power range in the market and the ability to manufacture custom ePDUs. They also offer an arrangement of outlets (number and type) for every region. Eaton ePDUs are distinguished for their quality, dependability and versatility.
Designed for reliable and cost-effective power distribution, Basic ePDUs have the form factor and receptacle choices to meet the needs of the demanding data center architect. With power levels ranging from 1.4 kW all the way to 17 kW, Eaton has the right Basic ePDU for any application. FlexPDUs and Hot Swap Maintenance Bypass (page 14) The Eaton FlexPDUs provide flexible output receptacle options from a single UPS.
Understanding ePDU technologies Why monitor? The unique monitoring function of Eaton ePDUs allows you to remotely monitor the current draw of individual outlets or sections over a network. This, combined with state-of-the-art software, allows the user to aggregate the information from hundreds of ePDUs in one location. All monitored ePDUs also include the Easy-Read digital LED ammeter for easy start-up and provisioning of servers.
Eaton offers a number of software management tools for you based on the number of ePDUs you need to manage.
Basic ePDUs Basic ePDUs - 0U Eaton Basic ePDUs provide reliable and cost-effective power distribution. Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) ePBZ98 ePBZ98 5-15P 15A 1.44 BA 6 0U (18) 5-15R 48.0 x 1.5 x 1.5 ePBZ89 ePBZ89 C14 None 1.44 BA 6 0U (16) C13 28.0 x 1.9 x 2.2 ePBZ75 ePBZ75 5-15P None 1.44 BA 15 0U (14) 5-15R 23.9 x 1.5 x 1.5 ePBZ73 ePBZ73 5-15P (1) 15A 1.44 BA 15 0U (18) 5-15R 48.
Basic ePDUs ePBZ89 ePBZ97 ePBZ93 PW105BA0U239 PW306BA0U244 PW314BA0U253 eaton.com/epdu 1.800.356.
Basic ePDUs Basic ePDUs - 1U Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101BA1U140 T982A1-N-SS-009 5-15P (1) 15A 1.44 BA 9 1U (12) 5-15R 1.75 x 19.0 x 7.0 ePBZ86 ePBZ86 5-15P None 1.44 BA 10 1U (12) 5-15R 1.7 x 17.3 x 2.3 ePBZ83 ePBZ83 5-15P None 1.44 BA 15 1U (12) 5-15R 1.7 x 17.3 x 2.3 T982A2-N-SS-009 5-20P (1) 20A 1.92 BA 9 1U (12) 5-20R 1.75 x 19.0 x 7.
Rear view Basic ePDUs Front view PW101BA1U140 ePBZ99 ePBZ88 ePBZ95 ePBZ94 Front view Rear view PW105BA1U163 Front view Rear view PW314BA1U193 eaton.com/epdu 1.800.356.
FlexPDUs and Hot Swap Maintenance Bypass FlexPDUs Eaton FlexPDUs increase power distribution from a single UPS. • 3-foot cord allows easy connection close to UPS without cable clutter • Mounting bracket attaches directly to UPS • Mounting bracket allows for vertical, 1U or UPS attachment Hot Swap MBP mounted in rack with 3U UPS Style Number Input Plug Breaker Max kW Function Cord (ft)1 Orientation Receptacles Dimensions (H x W x D, in) EFLX1500R-PDU1U 58015 5-15P None 1.
FlexPDUs and Hot Swap Maintenance Bypass FlexPDU mounted with 2U UPS EFLX1500R-PDU1U EFLX2000R-PDU1UL EFLXI3000R-PDU1UIEC EHBPL3000R-PDU1U eaton.com/epdu 1.800.356.
Monitored ePDUs Monitored ePDUs - 0U Eaton Monitored ePDUs enable you to remotely monitor the current draw of the unit and individual sections. Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101MI0U233 V70NA1-N-SS-109 5-15P None 1.44 MI 9 0U (24) 5-15R 66.0 x 2.0 x 1.89 PW102MI0U234 V70NA2-N-SS-109 5-20P None 1.92 MI 9 0U (24) 5-20R 66.0 x 2.0 x 1.89 PW102MI0U235 V70NA2-N-SL-109 L5-20P None 1.
Monitored ePDUs PW306MI0U247 PW309MI0U248 PW309MI0U250 PW309MI0U256 PW317MI0U222 eaton.com/epdu 1.800.356.
Monitored ePDUs Monitored ePDUs - 1U/2U Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101MI1U221 T982A1-N-SS-109 5-15P (1) 15A 1.44 MI 9 1U (12) 5-15R 1.75 x 19.0 x 7.0 PW101MI1U403 T982A2-F-SS-109 5-20P (1) 20A 1.92 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 PW102MI1U160 T982A2-N-SL-109 L5-20P (1) 20A 1.92 MI 9 1U (12) 5-20R 1.75 x 19.0 x 7.0 PW103MI1U161 T982C2-N-SL-109 L5-30P (2) 20A 2.
Eaton Advanced Monitored ePDU provides maximum power for both standard and blade server. Additionally this technology provides outlet level monitoring for capacity planning and energy management. Outlet Level Monitoring Input Plug1 Breakers Max kW Orientation Receptacles Dimensions (H x W x D, in) eAM008 3 L6-20P2 None 3.3 0U (20) C13, (4) C19 60.0 x 2.2 x 2.6 eAM001 3 L6-30P (2) 20A 5.8 0U (20) C13, (4) C19 68.0 x 2.2 x 2.6 eAM002 3 L21-20P None 5.8 0U (21) C13, (3) C19 60.
Switched ePDUs Switched ePDUs Eaton switched ePDUs provide remote power monitoring of both voltage and current and provide outlet-level control for on/off/reboot capabilities. Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PW101SW0U224 IPV70A1-EP1-09S 5-15P None 1.44 SW 9 0U (16) 5-15R 66.0 x 2.0 x 1.89 PW102SW0U150 IPV42A2-EP1-09L L5-20P None 1.92 SW 9 0U (8) 5-15R 42.0 x 2.0 x 1.
Switched ePDUs PW101SW0U224 PW102SW0U150 PW103SW0U152 PW103SW0U153 PW105SW0U154 PW309SW0U178 eaton.com/epdu 1.800.356.
Managed ePDUs Managed ePDUs Eaton Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor down to the individual outlet. Outlet Level Monitoring Outlet Level Switching Input Plug1 Breakers Max kW Orientation Receptacles Dimensions (H x W x D, in) eMA012 3 3 L6-20P2 None 3.3 0U (20) C13, (4) C19 60.0 x 2.2 x 2.6 eMA006 3 3 L21-20P None 5.8 0U (21) C13, (3) C19 60.0 x 2.2 x 2.6 eMA010 3 3 L6-30P (2) 20A 5.
Managed ePDUs Color-coded receptacles Advanced LCD display eMA012 eMA010 eMA009 eaton.com/epdu 1.800.356.
Managed ePDUs Managed Managed ePDUs allow you to monitor and control critical factors such as voltage, current and power factor down to the individual outlet.
The Eaton eATS ePDUs automatically transfer power from the primary source to a secondary source. Catalog Number Style Number Input Plug Breaker Max kW Function Cord (ft) Orientation Receptacles Dimensions (H x W x D, in) PWATSS515002 T2235-A1-NNB09S (2) 5-15P None 1.44 AT 9 1U (8) 5-15R 1.72 x 19.0 x 7.0 66027 (2) 5-15P None 1.44 AT 6 1U (6) 5-15R 1.72 x 19.0 x 9.8 PWATSS520003 T2235-A2-NNB09S (2) 5-20P None 1.92 AT 9 1U (8) 5-20R 1.72 x 19.0 x 7.
Eaton Automatic Transfer Switches Front view Rear view PWATSS515002 Front view Rear view PWATSL530007 Front view Rear view PWATSSC20001 Front view Rear view PWATSL630006 26 eaton corporation Enclosure Power Distribution Units
Full Load Receptacles Circuit Breaker EMI/RFI Filter Surge Suppression Input Plug IPC3401 1920 VA @ 120V~ 3840 VA @ 240V~ (8) C13 (2) 20A 20A 270V C20 Inlet IPC3401-NET 1920 VA @ 120V~ 3840 VA @ 240V~ (8) C13 (2) 20A 20A 270V C20 Inlet IPC3402 1920 VA (8) 5-15R (1) 20A 20A 270V C20 Inlet IPC3402-NET 1920 VA (8) 5-15R (1) 20A 20A 270V C20 Inlet IPC3402-A2 1920 VA (8) 5-20R (1) 20A 20A 270V C20 Inlet IPC3402-A2-NET 1920 VA (8) 5-20R (1) 20A 20A 270V C20 Inlet IP
Industrial ePDUs Intelligent Power Control IPC3600 Series Full Load Ethernet/ Serial Receptacles Circuit Breaker EMI/RFI Filter Surge Suppression Input Plug Cord (ft) Dimensions (H x W x D, in) IPC3601 1920 VA @ 120V~ 3840 VA @ 240V~ Yes (8) C13 (1) 20A 20A Yes C20 Inlet Not Included 1.7 x 19.0 x 19.5 IPC3602 1920 VA Yes (8) 5-15R (1) 20A 20A Yes C20 Inlet Not Included 1.7 x 19.0 x 19.5 IPC3601-F3-3316 5760 VA Yes (8) C13 (2) 15A No Yes L6-30P 10 1.7 x 19.0 x 19.
Catalog Number Full Load Receptacles EMI/RFI Filter Surge Suppression Cord (ft) Power Input Plug Serial Control (RS232) Ethernet Control Dimensions (H x W x D, in) IPC3400-A1 1440 VA (4) 5-15R 15A 270V 9 5-15P Yes No 3.4 x 9.0 x 5.8 IPC3400-A1-NET 1440 VA (4) 5-15R 15A 270V 9 5-15P Yes Yes 3.4 x 9.0 x 5.8 IPC3400-AB 1440 VA/2880 VA (4) C13 15A 270V 8 C14 Yes No 3.4 x 9.0 x 5.8 IPC3400-AB-NET 1440 VA/2880 VA (4) C13 15A 270V 8 C14 Yes Yes 3.4 x 9.0 x 5.
Industrial ePDUs North American TPC115-10 series single-phase systems 120V~ OR 240V~, 15A, 20A and 30A, 50/60 Hz Catalog Number Full Load Receptacles Circuit Breaker EMI/RFI Filter Multi-Stage Surge Suppression Cord (ft) Input Plug Dimensions (H x W x D, in) TPC115-10-A 1440 VA (10) 5-15R (1) 15A 20A 270V/150V 9 5-15P 1.7 x 19.0 x 8.0 TPC115-10-A2 1920 VA (10) 5-20R (1) 20A 20A 270V/150V 9 5-20P 1.7 x 19.0 x 8.
110-125V/200-240V~,16A, Single Phase, 50/60 Hz Catalog Number Circuit Breaker Multiple Time Delay EMI/RFI Filter Surge Suppression Receptacles Remote Control Cord (ft) Input Plug Dimensions (H x W x D, in) TPC2365 (1) 20A No Yes (20A) 320V (12) C13 Standard Not Included C20 Inlet 1.7 x 19.0 x 8.0 TPC2365/MTD (1) 20A Yes Yes (20A) 320V (12) C13 Standard Not Included C20 Inlet 1.7 x 19.0 x 8.
Industrial ePDUs North American TPC4100 series three-phase systems 120/208V~ Three-Phase WYE, 20A and 30A, 50/60 Hz Receptacles Circuit Breaker Remote EMI/RFI Filter Surge Suppression Cord (ft) Input Plug Dimensions (H x W x D, in) TPC4100-A2 (12) 5-20R (3) 20A No 30A 150V 9 L21-20P 1.7 x 19.0 x 9.5 TPC4100-B (12) 6-15R (3) 15A No 30A 270V 9 L21-30P 1.7 x 19.0 x 9.5 (6) 5-15R, (6) 6-15R (3) 15A No 30A 150V 9 L21-30P 1.7 x 19.0 x 9.
120/208V~ Three-Phase WYE, 30A, 50/60 Hz Catalog Number Main Secondary Unswitched Full Circuit EMI/ Circuit Duplex Surge Cord Load Per Receptacles Breaker RFI Breakers Circuit Suppression (ft) Phase (on/off Filter Per Phase Breaker switch) PC2641-D 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A 320V PC2641D-LT 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A 30A PC2641-D/ MTD 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A PC2641-D/LT 2880 VA (14) 5-20R (1) 30A (3) 20A (1) 20A Remote Contr
Industrial ePDUs North American PC975 series three-phase systems 120/208V~ Three-Phase WYE, 30A, 50/60 Hz Main Circuit Secondary Unswitched Breaker Circuit Duplex (on/off Breakers Circuit switch) Per Phase Breaker EMI/RFI Filter Surge Suppression Receptacles Cord (ft) Input Plug Dimensions (H x W x D, in) Catalog Number Full Load Per Phase PC975, PC975-LT 2880 VA (4) 30A (3) 2-Pole 20/20 20A thermal reset 30A 270V (8) 5-20R and (3) L6-20R 15 L21-30P 3.4 x 19.0 x 14.
120/208V~ or 230/400V~ Three-Phase WYE, 20A, 50/60Hz Catalog Number Full load Per Phase Main Circuit Breaker Receptacles EMI/RFI Filter Per Phase Surge Suppression Input Dimensions (H x W x D, in) PC302-I/MTD 1920 VA or 3680 VA (1) 20A (14) C13 20A 270V Terminal Block 3.4 x 19.0 x 14.5 PC302-I/LT 1920 VA or 3680 VA (1) 20A (14) C13 20A 270V Terminal Block 3.4 x 19.0 x 14.
Industrial ePDUs International PC2672 series three-phase systems 120/208V~ OR 230V/400V~, Three-Phase WYE, 30A, 50/60 Hz Catalog Number PC2672 Full Load Per Phase Circuit Breaker Secondary Listed Breakers, (1) Each For The C19 Outlets Secondary Listed Breakers, (1) Each For A Pair of C13 Outlets Receptacles EMI/RFI Filter Cord (ft) Dimensions (H x W x D, in) 2880 VA at 120/208V or 5520 VA at 230/400V (3) 30A (4) 16A (6) 10A (12) C13 (4) C19 (1) IEC309 32A 30A 5 5.2 x 19.0 x 16.
UPS extension systems Catalog Number Circuit Breaker Input Voltage Output Voltage EMI/RFI Filtering Surge Suppression Receptacles Cord (ft) Input Plug Dimensions (H x W x D, in) (4) 15A 120V~ / 30A 20V~ / 30A N/A N/A (8) 5-15R1 6 L5-30P 3.0 x 7.8 x 10.0 240V~ / 30A 240V~ / 30A N/A N/A (4) L6-30R 6 L6-30P 3.0 x 7.8 x 10.0 LPC120P LPC208-1P N/A LPC208-2P (3) 20A 240V~ / 30A 240V / 30A N/A N/A (3) L6-20R, (1) L6-30R 6 L6-30P 3.0 x 7.8 x 10.
Industrial ePDUs Remote control panels Allows immediate and complete ‘power off’ control from one button. Remote Type Dimensions (H x W x D, in) Color Receptacle Switch/EPO RCP100-GRY Standard 1.73 x 19.0 x 2.0 Gray None 2-position/normally open RCP100-BLK Standard 1.73 x 19.0 x 2.0 Black None 2-position/normally open RCP100-GRY-LT1 Latching 1.73 x 19.0 x 2.0 Gray None 3-position/normally closed RCP100-BLK-LT1 Latching 1.73 x 19.0 x 2.
Industrial ePDUs Sample remote circuits Standard remote control interface REMOTE START REQUIRES (2) CONDITIONS: 1. The on/off/remote switch must be in the remote position. 2. A maintained closure between pins 1 & 3 turns the unit on. REMOTE POWER OFF REQUIRES (1) CONDITION: Opening the maintained connection between pins 1 & 3 turns off the switched outlets.
Industrial ePDUs Industrial ePDUs environmental, surge suppression and EMI/RFI filter performance Chart 1: Chart 5: 025-3021 TVSS (Transient Voltage Surge Suppression) MOV Specifications EMI/RFI Filtering Common Mode Insertion Loss Mhz. Continuous AC Voltage 150 Vac 270 Vac 320 Vac Continuous DC Voltage 200 Vdc 360 Vdc 420 Vdc Max. DC Leakage 200 μA 200 μA 200 μA Low Varistor Voltage Limit 212 Vdc 389 Vdc 462 Vdc Mhz. High Varistor Voltage Limit 243 Vdc 453 Vdc 540 Vdc dB.
The Rack Power Module (RPM) delivers up to 36 kW (hardwire option required, BladeUPS connector limits to 12 kW) of power to loads of various voltages, power cords and layouts. The 3U RPM can be deployed in the same rack with the UPS and IT equipment; there’s no need for a dedicated infrastructure rack. The resulting architecture has fewer cables to manage, fewer distribution points to monitor and greater flexibility for IT personnel to make changes without an electrician.
ePDU plugs and receptacles ePDU plugs and receptacles Standard NEMA plugs 5-15 120V 15A 1 phase straight blade 6-20 208V 20A 1 phase straight blade L21-20 120/208V 20A, 3 phase wye L22-20 277/480V 20A 3 phase wye 5-20 120V 20A 1 phase straight blade L6-20 208V 20A 1 phase twist lock L21-30 120/208V 30A 3 phase wye L22-30 277/480V 30A 3 phase wye L5-20 120V 20A 1 phase twist lock L6-30 208V 30A, 1 phase L15-20 208V 20A 3 phase delta L5-30 120V 30A 1 phase twist lock L14-30 120/240V 30A 2 phase (
By turning to Eaton, you can enjoy one-stop shopping for a full range of power quality and power distribution needs, including power cables. The Eaton cable portfolio includes nearly two dozen choices in three product categories including adapters, jumpers and splitters. All Eaton power cables are tested and certified for use with Eaton products, such as ePDUs, rack power modules (RPMs) and UPSs— proven to deliver the reliability and service life needed for the most rigorous data center applications.
Space-saving mounting options Space-saving mounting options Installing your new ePDU is quick and easy. There are models that mount horizontally in minimal rack space (1U or 2U), or vertically in rack side pockets or rear channels—or on a wall or floor, saving traditional U space for IT equipment. The units come with all mounting hardware included, ready to install. There’s no need to purchase additional mounting hardware or accessories.
KIT-CABLRES-01 Transverse mounting KIT-CABLRES-08 • Prevent downtime and accidental disconnection • Secure cables/plugs to PDU • Cable ties provide highest level of retention • Black adjustable bracket versions allow front or rear mounting – KIT-CABLRES-01 - fits 9.
Racks and airflow management Racks and airflow management Once you’ve decided which Eaton ePDU is best for your application, it’s time to find the perfect rack to install them in. Eaton’s provides a full line of racks and airflow management solutions, for you to store, cool, power, manage and secure your critical IT equipment. To view our entire portfolio of solutions, please visit powerquality.eaton.com.
Racks and airflow management Active Airflow Manager Eaton’s HCS pressure based system with active airflow, when combined with best practices, improves performance metrics considerably. Allocating the correct amount of airflow at known intake locations is the key to reducing energy consumption while increasing equipment performance. Best practices such as blanking panels, proper perforated tile placement and the reduction of bypass airflow must be employed to ensure desired results.
UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 Toll Free: 1.800.356.5794 Eaton.com/epdu CANADA Ontario: 416.798.0112 Toll free: 1.800.461.