Specification

Catalog # OS106D1 Auto On Sensor Dimmer Catalog # VS106D1 Manual On Sensor Dimmer
SPECIFICATIONS
Single Pole
5A (600W) 120V AC 60 Hz.
• For Incandescent and Magnetic Low Voltage (MLV)
NOTE - A Neutral Connection is required in the wallbox where the sensor will be installed
D
ESCRIPTION
The OS106D1 or VS106D1 can replace a standard wall switch controlling an incandescent or
magnetic low voltage load.
The OS106D1 turns on automatically when a person enters the room.
The VS106D1 requires manual activation to turn on the lights.
• Both OS106D1 and VS106D1 will automatically turn off lights after a user selectable time
delay.
OS106D1 includes a light level adjustment for daylight to prevent motion from turning on the
l
ights if the daylight level in the room is bright enough that lights are not needed.
• OS106D1 and VS106D1 incorporates the ability to detect when rooms are only occupied very
briefly and shortens the time delay in order to save energy.
An LED indicates the load status and provides a momentary flash to indicate that
m
otion has been detected.
OPERATION INSTRUCTIONS
Auto ON Sensor Dimmer– OS106D1
OS106D1 will turn on lights automatically when a person enters the room
• The light level may be changed by pressing the dimmer bar – left side for dimming and right
side for brightening.
• Green LEDs in the dimmer bar indicate the light level.
• Green LED’s will dim when the dimmer is off.
• Lights will turn off automatically when no motion is detected after a selectable time delay.
• The selectable time delays are 5 seconds (Test Mode), 5 minutes (factory default), 15 minutes
and 30 minutes.
Manual ON Sensor Dimmer – VS106D1
• The VS106D1 must be turned on manually with the ON/OFF button.
• Lights will turn off automatically when no motion is detected after a selectable time delay.
• The light level may be changed by pressing the dimmer bar – left side for dimming and right
side for brightening.
• Green LEDs in the dimmer bar indicate the light level.
• Green LED’s will dim when the dimmer is off.
• The selectable time delays are 5 seconds (Test Mode), 5 minutes, 15 minutes and 30 minutes (factory default).
• When the lights have turned off due to a lack of motion, the lights will turn ON automatically if motion is detected within 10 seconds.
OS106D1 SPECIAL MODES
Reverse Mode: The reverse mode is used when the lights must stay OFF in a room while motion is detected. If the lights are ON, a double tap of the ON/OFF button will turn
off the lights and put the device into the Reverse Mode. This allows the lights to stay OFF as long as motion is detected. After the time delay is finished the sensor
operation goes back to normal.
Manual ON Only mode: This mode may be selected to prevent motion from automatically turning on the lights. Press and hold the ON/OFF button for 5 seconds until the
indicator LED blinks. Release the button while the LED is blinking. Repeat this procedure to restore normal operation. While the OS106D1 is in the manual ON mode, it will
behave like a VS106D1.
Override Mode: Turns off all motion sensing and allows the device to be used as a regular ON/OFF switch or in the unlikely event of a failure of the motion sensor. Press
and hold the ON/OFF button for 10 seconds until the indicator
LED blinks for the second time (the LED will also blink at the 5 second
point). Release the button while the LED is blinking. Repeat this
procedure to restore normal operation. This mode also can be used on
VS106D1.
INSTALLATION INSTRUCTIONS
WARNING:
• Turn OFF circuit breaker or remove fuse(s) and verify that power is off
before wiring.
• Never wire any electrical device with power turned on. Wiring the
device with the power on may cause permanent damage to the device
and void the warranty.
• If you are unsure about any part of these instructions, or if the wiring
does not match the descriptions given, you should call a qualified
electrician.
CAUTION:
1. Use only with 120V AC 60 Hz.
2. Must be installed and used in accordance with all applicable electrical
codes.
3. If a bare copper or green ground connection is not available in the wallbox,
contact a licensed electrician for installation. Do not install without proper
ground connections.
4. Do not exceed maximum device ratings.
O
CCDIM-PTA (REV. A)
ENGLISH
IINN UU..SS..AA..::
Cooper Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269 • 866-853-4293
0
15’
MAJOR MOTION
1000 SQ. FT.
36’
0
COVERAGE PATTERN
MINOR MOTION
300 SQ. FT.
8’
1
5’
8
15’
Light Fixture
White
Neutral
White
Neutral
White
Neutral
Ground
Bare Green
Black
Hot
Black
Hot
Black
Output
Red
WIRING DIAGRAM

Summary of content (2 pages)