Specifications
EAW Smaart 6 Operation Manual  Smaart 6 Commands
102
In real-time mode, averaging helps stabilize the live trace, making it easier to see trends 
in the data but slows down the display’s response to changes and can mask transient 
events. When selected, the Instantaneous function bypasses averaging but continues to 
update the averaging buffers in the background, allowing the display to be compared 
between averaged and instantaneous data without resetting the number of averages and 
waiting for the averaging buffers to rebuild. 
5.3.8 Reseed Averages
Choose Options->Reseed Averages or press the V keyboard key to flush the average 
buffers. This happens automatically when changes are made to averaging parameters, 
FFT size, or sampling rate, starting the analyzer, and switching between display types. 
5.3.9 High Contrast View
Choose Options->High Contrast View or press the H keyboard key to toggle the display 
to the high contrast view, which is easier to read outdoors or in bright light. 
5.4 Help Menu
5.4.1 About
Choose Help->About to display information about the currently installed version of 
Smaart. In Mac OSX, access the About box is from the Smaart Menu on the system’s 
shared menu bar. 
Figure 5-9 About screen
5.4.2 Smaart Help
Choose Help->Smaart Help to display the PDF of this manual.