Specifications
EAW Smaart 6 Operation Manual  Getting Started
20
1.4.9 Internal Delay Control
The Delay control (Figure 1-8) provides access to Smaart 6’s internal signal delay. The 
internal delay can provide up to 750 ms of delay (in 0.01 ms increments) for one of the 
two input signals, intended primarily to provide signal alignment for Frequency Response 
measurements. The delay selected and corresponding distance are displayed on the Delay 
control. To alter delay times by the increments specified in the Delay tab, use the up and 
down arrow buttons to the right of the readout field. Or, click the Delay readout and enter 
the desired delay time directly.
Auto Delay Locator Buttons
The Auto Sm and Auto Lg buttons (Figure 1-8) activate Smaart 6’s Automatic Delay 
Locator using the small or large time window preset, respectively. See Automatic Delay 
Locator on page 55 for more details.
1.4.10 Signal Level/SPL Display and Input Level Meters
Figure 1-10 Signal level, SPL, and input meters
The Signal Level/SPL Display provides a numeric readout of the overall signal level 
for the selected SPL Source channel (see Audio I/O on page 98) and can be calibrated 
to provide SPL readings.
The input level meters display the levels of the two input signals relative to the maximum 
input voltage (regarded as 0 dB) for the A/D converters on the selected input device. 
Each meter includes a clip indicator that lights if the input signal level exceeds the A/D 
converter’s maximum input voltage. Click the Mea Sig and Ref Sig to show/hide the 
corresponding signal on the RTA display.