Specifications
EAW Smaart 6 Operation Manual  Analysis Modes and Display Types
50
The Coherence Trace
The Coherence trace displays as a second trace in red in the upper portion of the fre-
quency/magnitude response plot if the Show Coherence Trace checkbox is selected in 
the Frequency Response tab of the Options dialog.
The Coherence trace is normally plotted in the upper half of the Magnitude display using 
the center line as zero and the top of the graph as its maximum value (100% = perfect 
coherence). As the mouse tracking cursor moves across the plot area, the coherence values 
for the current data point is displayed in red in the cursor readout above the plot.
Coherence Blanking 
Coherence Blanking is a technique of not looking at data whose coherence is too low. 
Coherence Blanking is similar to Magnitude Thresholding (see below) but works on 
coherence value rather than signal strength. The Coherence Blanking parameters are in 
the Frequency Response tab of the Options dialog (Figure 3-8).
Three parameters control Coherence Blanking:
Solid Above: The Coherence trace is drawn with a solid red line if the Coherence value 
is above the level set here. This value defaults to 80%, which would be considered a 
very reliable Coherence value for an acoustical measurement under ideal circumstances.
Invisible Below: The Coherence trace is not drawn if the Coherence value is below the 
value set here. This value defaults to 10% and would only rarely require a lower value.
Transparent in between with minimum opacity: Frequency Response (Magnitude 
and Phase) traces are drawn with variable transparency, based on coherence, where 
higher values are more opaque and lower values are more transparent. The minimum 
opacity value ensures data traces remain clearly visible all the way down to the mini-
mum acceptable coherence value (the Invisible Below threshold). The default for this 
minimum opacity value is 30%. Under difficult viewing conditions, you may want to 
set it higher to make low-coherence data more visible. Setting it to 100 effectively 
disables coherence blanking.
Figure 3-8 Coherence Blanking parameters in Frequency Response tab of Options dialog