Drawing : - TPC262 Issue :-8 Date : - 10/12/13 CD100E INDUSTRIAL DEHUMIDIFIER DEHUMIDIFIER OWNER’S MANUAL www.eipl.co.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 CD100E PACKAGE CONTENTS Item Description Quantity 1027500 Dehumidifier 1 Wall mounting bracket 1 3081315 M8 X 25 Hex head bolt 10 off 3081505 M8 Flat washer 10 off 3081525 M8 Spring washer 10 off 3088546 Red end cap 6 off 3088552 M8 Spring nut 10 off 3035998 Free socket 1 off 3014338 PVC tube – 12mm I/D 3M 3086101 Jubilee clip 1 off TPC262 Manual 1 off Page 2 of 18
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 UNPACKING Carefully remove the CD100 dehumidifier unit from its transit box and visually check for signs of transit damage. If there is evidence of damage DO NOT attempt to operate the unit, call your supplier for advice. Do not discard the packing; it will be useful when transporting the dehumidifier unit in the future. INTRODUCTION Dehumidifiers remove moisture from the air that is circulating through the unit.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 SPECIFICATIONS MODEL: CD100E HEIGHT: 406mm (16”) WIDTH: 914mm (36”) DEPTH: 508mm (20”) WEIGHT: 61 Kg (135 lbs) AIRFLOW: 1190 M3/hr (700 cfm) POWER 1090 W (max) POWER SUPPLY: 110V/120V, 1p, 50Hz/60Hz. FINISH: Vinyl Coated Steel Choice of Mobility Aids MOBILITY: – Wheels of Skid Handle REFRIGERANT R407c (0.54Kg) TYPE/QTY: "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 INSTALLATION POSITIONING: Position the dehumidifier unit in the center of the room to be conditioned if at all possible. However if a damp patch is particularly apparent the outlet grille should be pointed towards it. NOTE: Both inlet grille and outlet grille of the dehumidifier unit must have clear space around them and not be obstructed in anyway. WIRING: Connect the power cord of the dehumidifier to a suitable single phase, fused power supply.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 OPERATION The operation of the dehumidifier is to remove moisture from the air by having it condense on the cool tubes of the evaporator coil. The air then passes over the hot condenser and returns to the conditioned space slightly warmer and at reduced moisture content. To concentrate drying all doors and windows should be kept closed.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 WARNING: • • Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 SPECIAL FEATURES HEATED CONDENSATE DRAINAGE TUBE: The CD100E dehumidifier is fitted with a heater tape which runs the length of the condensate tube. The effect of this heated condensate drainage tube will ensure that the drainage point for the dehumidifier is kept free from ice when operated in low ambients.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON ITEMS 1, 2, 3, 4, AND 5. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 TROUBLESHOOTING SYMPTOM Unit inoperative (no red light) CAUSE 1. No power to unit REMEDY 1. Check the power supply and fuse 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 4. Contact the Factory Service Center 1. Contact the Factory Service Center 2.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 CD100E SPARE PARTS LIST Part Description Number 1600500 DEFROST TIMER 3014251 3014338 CAPILLIARY TUBE .047 2 pcs.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 CD100 / CD100E WALL MOUNTING BRACKET KIT PART NUMBER 1027301 KIT CONTENTS: Item Qty Description 1 2 Frame Hook Rail 2 1 Frame Location Angle 3 1 Frame Top Angle 4 2 Frame Bottom Angle 5 2 ‘U’ Channel With Foot 6 2 Frame Support 7 3 3/16” Dome Head Rivet 8 10 M8 X 25mm Hex Head Screw 9 10 M8 Spring Washer 10 10 M8 Flat Washer 11 10 M8 Spring Nut and Plate 12 6 End Cap 13 1 Mounting Fame Assembly 1027301 14 1 Installa
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 Assembly Instructions: With reference to the table above unpack the Mounting Frame Kit and check for completeness. With reference to Drawing 1027301 Assemble the mounting frame as follows:1. Using Items 8, 9, 10, 11 assemble Items 4 and 5 ensuring the edge of the foot is flush with the end of Item 4. 2. Using Items 8, 9, 10, 11 assemble Items 5 and 3 ensuring the distance of 900mm +/- 2mm is maintained over Items 4. 3.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labor required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit.
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 Page 16 of 18
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 Page 17 of 18
Drawing : - TPC262 Issue :-8 Date : - 10/12/13 UK Head Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD American Sales Office German Sales Office Ebac Industrial Products Inc Ebac Industrial Products Ltd. 700 Thimble Shoals Blvd. Gartenfelder Str.