Manual

Figure 5. Cartridge Seal Assembly
CAUTION!
This seal is not designed for operation at
temperatures above 160 º F (71º C). Do not use
at higher operating temperatures.
If the seal plate was removed, install the seal plate
gasket (4). Position the seal plate over the shaft and
secure it to the bearing housing with the hardware.
To prevent damaging the shaft sleeve O-ring on the
shaft threads, stretch the O-ring over a piece of
tubing 1-1/4 I.D. x 1-1/2 O.D x 2 inches long (32mm
x 38mm x 51mm).
SEAL PLATE
O-RINGS
SLEEVE
O-RING
INTEGRAL
SHAFT
SLEEVE
SHEAR
RING
(SHEARED)
STATIONARY
SEAT
STATIONARY
ELEMENT
ROTATING
ELEMENT
DRIVE BAND
SPRING
CENTERING
WASHER
BELLOWS
IMPELLER
SHAFT
IMPELLER
SHIM S
IMPELLER
SPRING
RATAINER
EBARA Fluid Handling
31