A WARNING: For Outdoor Use Ol Installation and service must be performed by a qualified installer; service agency, or the gas supplier. £\ DANGER FIRE OR EXPLOSION HAZARD H reservoirs: Shut:off gasitothe:appliance. « Extinguish any open flame. & |f odor continues, leave the area immediately. = After leaving the ares; call our gas supplier fire department: ® Failure to follow these instructions could result in fire or explosion, Which could cause property damage, personal injury, or death.
LIMITATION OF WARRANTY AND LIABILITY NOTICE: Read this Limitation of Warranty and Liability Before Using This Product. If the Terms Are Not Acceptable, Return the Product at Once, Unopened, and the Purchase Price Will Be Refunded. It is impossible to eliminate all risks associated with the use of this product. Such risks arise from weather conditions, the manner of use or application, or other unknown factors, all of which are beyond the control of the Seller and Manufacturer.
Part A. SAFETY INFORMATION Before you assemble or operate this unit, please read carefully this entire Owner’s Manual. Failure to do so may result in a fire, explosion, injury or death. The Installation of this unit must adhere to local codes or ether the National Fuel Gas Code, ANSI 2223. 1/NFPA54, OR National Gas and Propane WARNING Installation Code. * THIS UNIT IS INTENDED FOR OUTDOOR USE ONLY! This product shall be used outdoors, In a ventilated space and shall not be used In any enclosed area.
+ DO NOT fill tank over 80% full. * The tank system must be set up for vapor withdrawal. * STOP using if any part of the Propane Gas Tank is damaged. Rust and dents in tank may be hazardous and should be inspected by a Gas Supplier. « DO NOT burn anything other than the provided materials for this Fire Table. + Keep away from the unit for the first 30 minutes after Igniting your unit for the first time, as lava rocks could pop out and cause injury. Should any rocks pop out, discard them.
+ Keep the appliance area clear and free from combustible material, gasoline and other flammable vapors and liquids. + If the flame goes out while burning, turn the gas valve off. Wait 5 minutes before repeating the initial lighting procedure. Once you have a flame started, hold down the control knob for 1 minute. * DO NOT add water into the unit. * DO NOT operate ult If any part has hen under water. Immediately call for a Qualified Service Technician to Inspect the appliance.
= Children and adults should be alerted to the hazards of high surface temperatures and should stay away o avoid burns of-clothing ignition, »Young children: MUST BE carefully supervised at all times when they are in the area of this appliance. » Clothing or other flammable materials shall NOT be hung from the appliance or placed on or near the appliance; s Any guard or either protective device removed for servicing the appliance shall be replaced prior to operating and use of this appliance.
Part B IGNITION CONTROL BOARD Here below is:an exact visual display.
User's Guide to Parts and Accessories of The Regulator, Charge Valve of the Cylinder and Steps to Connecting the Gas Tank to the Fire Table /Column. Part C This Safety Information passage holds information that : 1) shows you the Regulator { per-connected to the Fire Table / Column ) 2) the Charge Valve of the Gas Tank and Its relevant Valves. There are Fire Table / Column that holds the Gas Tank INTERNALLY and EXTERNALLY. The Owner / User must know all the different parts : Charge Valves and Regulator.
Part D. Column. User's Guide : Loading of Gas Tank into the Fire Table 6507 Fire table must be 60 inches away from the gas tank A Please be careful not to trip over the gas pipe WARNING Part E. Cylinder. User's Guide : Connecting the Fire Table / Column to the Gas This next step guldens you to connect the Fire Table / Column Regulator to the Gas Cylinder.
Part F. FIRE TABLE / COLUMN PARTS INTRODUCTION Your Fire Table / Column Is delivered per-assembled whereby there Is no assembly actions needed. Here below Is an Introduction to all the parts that forms your Fire Table / Column. Each part Is different and holds Its own function. DO NOT attempt to change and or remove any part(s) thereof. In the event of servicing and or operational Issues, contact Qualified Services Technical Supper and or seek Squalled Service Technician.
Tabulated here below are the description to all parts as shown In above Picture . item Replete Description: L4 Burner Ring 02 Guard i 03 ; ‘Thermonuclear : o4 Ground Wire . 05 ? Ignition Pin A\ 6 Burner Plate o7 The control panel 08 CSA Warning Label 09 Tank cover 10 Man Frame of Fire Table 1" Nozzle 12 Corrugated Pipe 13 Switching Valve 14 Regulator Valve with Gas Hose 15 Control Knob 16 Ignition 17 Foot
arts al dories a m Tabulated here below Is the User's Glued to various Parts and Accessories to form your complete Fire Table /Column. Before you start to assemble this product, make sure all parts are present. ‘Compare parts with package contents list. If any parts are missing or damaged, DO NOT attempt to assemble the product.
USER'S INSTRUCTIONS Tabulated hare below are the basic spats to help you light and use your Fire Table / Column. STEP 1. Check that the Control Knob (15) for the gas supply system is turned to the “OFF” position before starting any assembly. STEP 2 2. Remove the Electronic Ignition Cap (16) on the electronic Ignition (16) by unscrewing and slide the Battery (B) Into the battery slot (16). Make sure the positive side of the Battery( B } faces outwards.
STEP 4 1 Step 1: Place a 20 b Quid propane gas (LP} tank (ot included) in the mass’ stand Wake sure the gas tank sits on the metal stand completely. Step 2: Turn the wing resew on the outer part of peal stand clockwise o secure the gas tank tightly. Step 3: Conn act the regulator o gas tank Doughy the Bottom of the metal stars. Step 4 Put the cover on the metal stand . Lt b WARNING** There is uot road on the gas caver tank I you want b cheek the gas pipes just Bold the aif vents and remove the gas tank.
Guard DO NOT PLACE LAVA ROCKS ON THE GUARD. KEEP GUARD CLEAR . A WARNING CORRECT To ensure proper function, the Guard (02) on the Burner (1) should never have lava rocks (A) covered overt.
Before performing a leak test, be sure: 1.) DO NOT press the Ignition . 2.) You are In a spacious outdoor area. Connect the Propane Gas tank to the Regulator (14/19 ) and turn the Valve (22) on the unit to the “OFF” position. Brush soap and water mixture onto all connections. Turn the gas supply on;if extra large bubbles form on any connection there may be a leak. If you smell gas or a leak is discovered, IMMEDIATELY turn the gas valve off, disconnect Propane Gas tank.
Before each use, inspect the Gas Hose (14). Replace Gas Hose(14) if there are any signs of cutting, wear or abrasion. Before you light your Fire Table / Column, please proceed / adopt the following steps : 1. Make sure the Control Knob (15} is in the “OFF” position. 2. Slowly open the Valve ( 22) on the Propane Gas Tank by turning the Control Knob {15) counterclockwise. 3. Push and hold In the Electronic Ignition (16 ) to create sparks within the electrode continue to hold. 4.
SAFETY INFORMATION : TO SHUT DOWN YOUR FIRE TABLE / Part L. COLUMN To Shut Down your Fire Table / Column, please proceed / adopt the following steps : 1. Turn Control Knob (15) clockwise to the “OFF” position. 2. Close the Cylinder Valve ( 21) on the Propane Gas tank If you DO NOT Intend to use It for a long time. Part M. MAINTENANCE FIRE TABLE / COLUMN « Before performing any maintenance work, ensure the Control Knob (15) is in the "OFF" position and always disconnect Propane Gas tank.
Part N. MAINTENANCE : FIRE TABLE / COLUMN SURFACE CARE * Our Table / Column Fire Table material has been sealed with a treatment that prevents staining and moisture absorption, and for product longevity this Fire Table / Column would still require proper care and maintenance to ensure the Integrity of the surface.
Part O. TROUBLE SHOOTING Here below Is a simple glued on frequently asked questions / frequently occurring Issues. Read through carefully and execute accordingly and adequately. Whenever you are uncertain, please contact Qualified Technician Services and/or Fire Department.
Part P. WARRANTY The manufacturer warranty shall be voided, and manufacturer disclaims any responsibility for the following actions whereby the Customer / Consumer / Owner has : + Made mollification) to the unlit and / or components Including the Gas Valve assembly. The Owner shall contact the Local Supplier and Qualified Service Person to repair these parts.