2
Technichal data / Heater
Version
Heating medium
Control of the heat flow
Heat flow (watt) D3 Camper
D4 / D4S
D4 Camper / D4 Camper plus
Heater air flow rate without D3 Camper
counterpressure D4 / D4S
(kg/h) D4 Camper / D4 Camper plus
Heater code D3 Camper / D4 / D4 Camper
D3 Camper / D4 / D4 Camper
D4S / D4 Camper plus
Fuel consumption (l/h) D3 Camper
D4 / D4S
D4 Camper / D4 Camper plus
Elektr. power (watt) D3 Camper
in operation (12 and 24 volt) D4 / D4 S
D4 Camper / D4 Camper plus
at Start (12 and 24 volt)
in the control phase „OFF“
Rated voltage
Operating range
Lower voltage limit:
An undervoltage protection in the controller
switches the heater off on reaching approx.
10.5 volt resp. 21 volt.
Upper voltage limit:
An uppervoltage protection in the controller
switches the heater off on reaching approx.
16 volt resp. 32 volt.
Fuel
„Fuel quality“ and „Fuel at low
temperatures“ see page 28.
Tolarable operating temperature Operation
Storage
Noise emission – passenger compartment
Maximum air intake temperature
Interference suppression
Weight
AIRTRONIC M for diesel
D3 Camper / D4 / D4S / D4 Camper / D4 Camper plus
Air
Stage
Power Large Medium Small
3000 2200 1600 900
4000 / 3500 3000 2000 1000
4000 / 3500 3000 2000 900
150 120 90 60
185 / 160 150 / 140 110 / 100 65 / 60
185 / 160 150 / 140 110 / 100 60 / 55
3 for outlet hood Ø 75 mm
10 for outlet hood Ø 90 mm
10 for outlet hood Ø 75 mm
0.38 0.28 0.2 0.11
0.51 / 0.44 0.38 / 0.38 0.25 / 0.25 0.13 / 0.13
0.51 / 0.44 0.38 / 0.38 0.25 / 0.25 0.11 / 0.11
24 16 10 7
40 / 40 24 / 30 13 / 16 7 / 8
40 / 40 24 / 30 13 / 16 7 / 8
<100
4 to 5
12 or 24 volt
approx. 10.5 volt resp. 21 volt
Undervoltage protection trigger time: 20 seconds
approx. 16 volt resp. 32 volt
Overvoltage protection trigger time: 20 seconds
Commercially available diesel fuel (DIN EN 590)
–40 °C to +70 °C
–40 °C to +85 °C
The maximum noise pressure level is <60 db (A), measured in the
opertating mode power stage „Large“,
as per 3.GSGV resp. DIN 45 635, part 1.
+40 °C
Interference suppression class 5 to DIN EN 55 025 for VHF, HF, MW
Interference suppression class 4 to DIN EN 55 025 for LW
approx. 4.5 kg