Technical data
Working Voltage: 12 Volts
GSM Bands: Dual Band EGSM900
GSM1800
GSM Class: Small MS
Transmit Power: Class 4 in EGSM900
Class 1 in GSM1800
Operating Temperature: 20 °C to +50 °C
Storage Temperature: 30 °C to +85 °C
Dimensions: 140 x 100 x 36 mm
You must insert the SIM card before you can use the
CALLTRONIC
:
To release the lock on the SIM cardholder, press
the yellow button the SIM cardholder springs out
a bit.
Pull out the SIM cardholder.
Insert SIM card with chip (contacts) facing
upwards.
Re-insert the SIM cardholder in the appliance,
until it locks into place.
Note:
Only SIM cards without a PIN and with 3-volt
technology can be used.
Installation of the operating elements
Push-button
Fit the enclosed push-button in the view of the driver
(Drill hole 10 mm, max. wall thickness 2.5 mm).
Connect the cables in accordance with the circuit
diagram.
Mini-clock (Option)
Install the mini clock (separate add-on) in accord-
ance with the instructions supplied. Connect the
cables in accordance with the circuit diagram.
Insert the SIM card
Insert the fuse and check the function
The operating element must be connected and fully
functioning before inserting the fuse.
Insert the
CALLTRONIC
(5 A) fuse and check the
function of the
CALLTRONIC
after approx. 30 sec-
onds (time until the GSM module has signed on to
the network) with a telephone or mobile phone.
Please note!
The heater diagnosis cable (blue / white) must be
connected for fault recognition (only for trade appli-
ances retrofit).
The operating element must be connected and fully
functioning before inserting the fuse. The appliance
detects whether a push-button or a mini-clock is
connected when the voltage supply is applied for
the first time. The
CALLTRONIC
does not accept
subsequent changes.