Data Sheet

Product Data Sheet 8850 N
02/04/2019 page 6 of 9
3.2 Electrical Features
Locked rotor protection
Impedance
Locked rotor current at
3.3 Aerodynamics
Measurement
conditions:
Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C;
In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft
horizontal.
The information is only valid under the specified test conditions and may be changed by the
installation conditions. If there are deviations from the standard test conditions, the
characteristic values must be checked under the installed conditions.
a.) Operation condition:
2.150 1/min at free air flow
Frequency: 50 Hz
Max. free-air flow (p = 0 /
= max.)
36,0 m3/h
Max. static pressure (p = max. /
=0)
25 Pa
b.) Operation condition:
2.500 1/min at free air flow
Frequency: 60 Hz
Max. free-air flow (p = 0 /
= max.)
41,0 m3/h
Max. static pressure (p = max. /
=0)
34 Pa