3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features
Condition
Symbol
Values
Voltage range
U
16 V
28 V
Nominal voltage
U
N
24 V
Power consumption
p = 0
0010
P
1,3 W
2,7 W
3,5 W
Tolerance
+- 20 %
+- 15 %
+- 15 %
Current consumption
p = 0
0010
I
81 mA
112 mA
125 mA
Tolerance
+- 20 %
+- 15 %
+- 15 %
Speed
p = 0
0010
n
7.500 1/min
11.400 1/min
13.000 1/min
Tolerance
+- 15 %
+- 10 %
+- 10 %
Starting current
consumption
650 mA
3.2 Electrical Features
Electronic function
Speed-Controlled
Reversed polarity protection
Rectifying diode
Max. residual current at U
N
I
F
<= 50 uA
Locked rotor protection
Auto restart
Locked rotor current at U
N
I
block
approx. 650 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 0,45 s / 4,5 s
First pulse t5 typical 0.7s (0.5 .. 1.0s) followed by t4. Afterwards cyclical t3/t4.