Data Sheet

Product Data Sheet 612 NGLE
02/04/2019 page 4 of 8
3 Operating Data
3.1 Electrical Operating Data
Measurement
conditions:
Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up
time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area
should not be any solid obstruction within 0,5 m.
p = 0:
corresp. to free air flow (see chapter aerodynamics)
I:
corresp. to arithm. mean current value
Features
Condition
Symbol
Values
Voltage range
U
8,0 V
15,0 V
Nominal voltage
U
N
12,0 V
Power consumption
p = 0
0010
P
0,3 W
0,58 W
0,9 W
Tolerance
+- 17,5 %
+- 12,5 %
+- 17,5 %
Current consumption
p = 0
0010
I
37 mA
48 mA
55 mA
Tolerance
+- 17,5 %
+- 12,5 %
+- 17,5 %
Speed
p = 0
0010
n
1.530 1/min
2.500 1/min
3.200 1/min
Tolerance
+- 10,0 %
+- 7,5 %
+- 10,0 %
Starting current
consumption
150 mA
3.2 Electrical Features
Electronic function
None
Reversed polarity protection
Rectifying diode
Max. residual current at U
N
I
F
< 50 uA
Locked rotor protection
Auto restart
Locked rotor current at U
N
I
block
approx. 150 mA
Clock signal at locked rotor
t
3
/ t
4
typical: 1 s / 5 s