Data Sheet

Product Data Sheet QG030-303/14
02/06/2019 page 6 of 8
4.2 Climatic Requirements
Humidity requirements
humid heat, constant; according to DIN EN 60068-2-78, 14 days
Water exposure
None
Dust requirements
None
Salt fog requirements
None
Permitted application area:
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly
exposure to water must be avoided.
Pollution degree 1 (according DIN EN 60664-1)
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact.
4.3 Mechanical Requirements
Please require severity levels and specification parameters from the responsible development departments.
5 Safety
5.1 Electrical Safety
Dielectric strength
DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE
0700)
A.) Type test
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C.
No arcing or breakdown is allowed!
All connections together to ground.
500 VAC / 1 Min.
B.) Routine test
Measuring conditions: At indoor climate.
No arcing or breakdown is allowed!
All connections together to ground.
850 VDC / 1 Sec.
Isolation resistance
Measuring conditions: After 48h of storage at 95%
R.H. and 25°C measured with U=500 VDC for 1 min.
RI > 10 MOhm
Clearance / creepage distance
1,0 mm / 1,2 mm
Protection class
III
5.2 Approval Tests
CE
EC Declaration of Conformity
Yes
EAC
Eurasian Conformity
Yes
UL
Underwriters Laboratories
Yes / UL507, Electric Fans
VDE
Association for Electrical, Electronic and Information
Technologies
Yes / Approval acc. to EN 60950 (VDE 0805) - Information
technology equipment
CSA
Canadian Standards Association
Yes / C22.2 No. 113 Fans and Ventilators
CCC
China Compulsory Certification
Not applicable