Data Sheet
Product Data Sheet 4412/2HHP
   01/30/2019  page 8 of 10 
3.6  Sound Data 
Measurement 
conditions: 
Sound pressure level: 1 meter distance between microphone and the air intake. 
Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) 
Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) 
For further measurement conditions see chapter aerodynamics. 
a.) Operation condition: 
5.000 1/min at free air 
flow 
PWM 100 %;  
Optimal operating point 
170,0 m3/h @ 81 Pa 
Sound power level at the optimal operating 
point 
6,4 bel(A) 
Sound pressure level at free air flow, 
measured in rubber bands 
55,0 dB(A) 
4  Environment 
4.1  General 
Min. permitted ambient temperature TU min. 
-20 °C 
Max. permitted ambient temperature TU max. 
70 °C 
Min. permitted storage temperature TL min. 
-40 °C 
Max. permitted storage temperature TL max. 
80 °C 
4.2  Climatic Requirements 
Humidity requirements 
humid heat, constant; according to DIN EN 60068-2-78, 14 days 
Water exposure 
None 
Dust requirements 
None 
Salt fog requirements 
None 
Permitted application area:  
The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly 
exposure to water must be avoided. 
Pollution degree 1 (according DIN EN 60664-1) 
There is either no pollution or it occurs only dry, non-conductive pollution. The pollution has no negative impact. 
Please require severity levels and specification parameters from the responsible development departments. 