Instruction Manual

Operating instructions
D2E133-DM47-23
Translation of the original operating instructions
3.2 Nominal data
Motor M2E068-DF
Phase 1~ 1~
Nominal voltage / VAC 230 230
Frequency / Hz 50 60
Type of data definition ml ml
Valid for approval /
standard
CE CE
Speed / min
-1
1650 2200
Power input / W 175 185
Current draw / A 0.78 0.82
Motor capacitor / µF 3 3
Capacitor voltage / VDB 450 450
Min. back pressure / Pa 100 250
Min. ambient
temperature / °C
-25 -25
Max. ambient
temperature / °C
40 40
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive No
Specific ratio
*
1.00
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes 25.5 25.3 32.3
Efficiency grade N 37.2 37 44
Power input Pe / kW 0.14
Air flow qv / m³/h 495
Pressure increase total psf / Pa 270
Speed n / min
-1
2295
Data established at point of optimum efficiency
3.4 Technical features
Mass 4. kg
Size 133 mm
Surface of rotor Partially cast in aluminium
Material of impeller Sheet steel, hot-galvanised
Housing material Sheet steel, hot-galvanised
Motor suspension Motor mounted via brackets on one side
Direction of rotation Clockwise, seen on rotor
Type of protection IP 44; Depending on installation and
position
Insulation class "B"
Humidity class F0
Mounting position Any
Condensate discharge
holes
None
Operation mode S1
Motor bearing Ball bearing
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Motor protection Thermal overload protector (TOP) wired
internally
Cable exit Axial
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval GOST; CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 10985-5-9970 · Revision 71618 · Release 2010-08-03 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com