User guide

Operating instructions
D2E140-HR97-07
Translation of the original operating instructions
3.2 Nominal data
Motor M2E068-CF
Phase 1~ 1~
Nominal voltage / VAC 230 230
Frequency / Hz 50 60
Type of data definition fa fa
Valid for approval /
standard
CE CE
Speed / min
-1
1150 1050
Power input / W 130 130
Current draw / A 0.58 0.58
Motor capacitor / µF 2 2
Capacitor voltage / VDB 400 400
Capacitor standard P2 (CE) P2 (CE)
Min. back pressure / Pa 0 0
Max. ambient
temperature / °C
50 40
Starting current / A 0.57 0.59
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Technical features
Mass 2.3 kg
Size 140 mm
Surface of rotor Uncoated
Material of impeller PP plastic, white
Housing material PP plastic, black
Motor suspension Motor mounted via brackets on one side
Direction of rotation Clockwise, seen on rotor
Type of protection IP 44
Insulation class "F"
Humidity class F0
Mounting position Any
Condensate discharge
holes
None
Operation mode S1
Motor bearing Ball bearing
Speed steps 4
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Electrical leads Via terminal box, integrated capacitor
connected via terminal box; With plug
Motor protection Thermal overload protector (TOP) wired
internally
Cable exit Variable
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval CCC; VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11081-5-9970 · Revision 72138 · Release 2010-09-23 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com