3.2 Nominal data
Motor M2E068-DF
Phase 1~ 1~
Nominal voltage / VAC 230 230
Frequency / Hz 50 60
Type of data definition fa ml
Valid for approval /
standard
CE CE
Speed / min
-1
1350 1750
Power input / W 195 215
Current draw / A 0.86 0.94
Motor capacitor / µF 5 5
Capacitor voltage / VDB 400 400
Capacitor standard P2 (CE) P2 (CE)
Min. back pressure / Pa 0 150
Min. ambient temperature
/ °C
-25 -25
Max. ambient temperature
/ °C
45 40
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive No
Specific ratio
*
1.00
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes / % 25.6 25.6 32.6
Efficiency grade N 37 37 44
Power input Pe / kW 0.16
Air flow qv / m³/h 455
Pressure increase total psf / Pa 331
Speed n / min
-1
2315
Data definition with optimum efficiency.
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass 3 kg
Size 146 mm
Surface of rotor Partially cast in aluminium
Material of terminal box PP plastic, black
Material of impeller PP plastic, white
Housing material PP plastic, black
Motor suspension Motor anti-vibration mounted on both sides
Direction of rotation Counter-clockwise, seen on rotor
Type of protection IP 20
Insulation class "F"
Humidity class F0
Mounting position Any
Condensate discharge
holes
None, open rotor
Operation mode S1
Motor bearing Ball bearing
Speed steps 4
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
< 0.75 mA
Electrical leads Via terminal box, integrated capacitor
connected via terminal box; With plug
Motor protection Thermal overload protector (TOP) wired
internally
Cable exit Variable
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-2-31; CE
Approval CCC; VDE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 11072-5-9970 · Revision 72138 · Release 2013-07-24 · Page 5 / 9