Manual
Operating instructions
D3G146-AH50-01
Translation of the original operating instructions
4.4 Connection screen
Line No. Signal Colour Function / assignment
4 L black Power supply 230 VAC, 50-60 Hz, see type plate for voltage range
3 N blue Neutral conductor
1 PE green/
yellow
Protective earth
8 0-10 V PWM yellow Control input 0 - 10 V or PWM, electrically isolated
9 Tach white Tach output: open collector, 1 pulse per revolution, electrically isolated
11 10V / max 1.1
mA
red Voltage output 10 V / max. 1.1 mA, electrically isolated
12 GND blue GND - Connection for control interface
Item no. 51220-5-9970 · Revision 67974 · Release 2012-02-21 · Page 7 / 10