4.4 Connection screen
No. Conn. Designation Colour Function / assignment
CON10 10.1 PE Protective earth
CON10 10.2 L black Power supply 230 VAC, 50-60 Hz, see type plate for voltage range
CON10 10.3 N Neutral conductor
CON11 11.1 10 V/max. 1.1
mA
Voltage output 10 V, 1.1 mA, electrically isolated, not short-circuit-proof
CON11 11.2 Tach Tach output: Open collector, 1 pulse per revolution, electrically isolated, Isink max = 10 mA
CON11 11.3 0-10 V PWM yellow Control input 0-10 V or PWM, electrically isolated
CON11 11.4 GND blue GND connection for control interface
Item no. 51142-5-9970 · ENG · Revision 83605 · Release 2014-11-03 · Page 8 / 10