4 Technical Specifications
4.3 ECI-63.60-K4
Nominal data
Type Unit ECI-63.60-K4-D00
Nominal voltage (U
N
) V DC 48
Allowable supply voltage range (U
ZK
) V DC 40 … 53
Nominal speed (n
N
) rpm 4000
Nominal torque (M
N
) mNm 850
Nominal current (I
N
) A 8.6
Nominal output power (P
N
) W 356
Free-running speed (n
L
) (no-load speed) rpm 5800
Free-running current (I
L
) (no-load current) A 0.60
Max. reverse voltage V DC 58
Setpoint input Analog / PWM / Frequency / Digital
Recommended speed control range rpm 0 … 5000
Locked rotor protection – thermal
Protection on overload – yes
Starting torque mNm 3 × M
N
Rotor moment of inertia (J
R
) kgm
2
× 10
-6
57
Thermal resistance (R
th
) K / W 2.5
Degree of protection (IP rating) IP 40 / IP 54*
Allowable ambient temperature range (T
U
) °C 0 … +40
Motor mass (m) kg 1.5
Order No. (ECI-63.60-K4 S) Connector type 932 6360 402
Order No. (ECI-63.60-K4 L) Stranded (litz) wire type 932 6360 405
Subject to change without notice * The degree of protection (IP 54) given refers to the connector type and the installed condition with
seal on the flange side.
F
axial
F
radial
L
1
F
axial
150 N
F
radial
150 N L
1
20 mm
Allowable shaft load at nominal speed and life
expectancy L10 about 20000 h**.
200 400 600 800 1000
1000
2000
3000
4000
5000
M
I
2,5
5,0
7,5
10,0
12,5
0
ECI-63.60-K4-D00
Torque [mNm]
Speed [min
–1
]
Current intensity [A]
Dimensions ECI-63.60-K4
Connector type
158,5
±0,3
Ø63
+0,1
-0,3
20
±0,3
Ø10
g5
16,3
Ø63,5
5,8
18,4500±10
Stranded wire type (cable harness is supplied separately)
NOTE