User guide

31
6 Parameterisation
6.1.3 “default” memory area
The default values loaded in the factory are stored in the “default” memory area. The operating data can be reset to the as-delivered
condition by using the “reload” command. The data is written in the “custom” and “RAM” areas.
Access to parameterisation with “customer access key” (password).
“Kickstart”
RS485
Drive memory area
external RAM custom default
Parameter
(application
function)
Parameter
(application
function)
reload
Parameter
(application
function)
write
store
Parameter
(application
function)
read power up reload
Parameter
(application
value)
Parameter
(application
value)
reload
Parameter
(application
value)
write
store
Parameter
(application
value)
read power up reload
Parameter
(HW set val)
Parameter
(HW set val)
power up
Parameter
(HW set val)
Parameter
(HW set val)
Parameter
(Offset single
sensor)
power up
Parameter
(Offset single
sensor)
Parameter
(Offset single
sensor)
Blue arrow = Command is executed in the operational status (clockwise, counterclockwise, braking / positioning)
Black arrow = Command is executed in the state unlock (motor in freewheel)
NOTE
With the command „Save“, the „user access key“ is reseted.
The “store” command is used to reset the “customer access key”.