User guide

60
7 Parameterisation of the Operating Modes
7.24 Operating mode 63: Rotational direction; distance
NOTE
In order for the parameter to function, KP_H must be > 0.
Function IN 1: Selecting the rotational direction.
Function IN 2: Travel distance; the distance increases with each high flank (x); displacement = x*distance.
Speed Current limit
IN A IN B IN 1 IN 2 Direction Value Type Value Function Comment
0 0 x x - 0 - - Free-wheeling No braking, no current feed
1 0 0 x pos A1 S P N control
1 0 1 x neg A1 S P N control
1 0 0 x pos A1 S P N control
1 0 1 x neg A1 S P N control
0 1 0 x neg A1 S P N control
0 1 1 x pos A1 S P N control
0 1 0 x neg A1 S P N control
0 1 1 x pos A1 S P N control
1 1 0 0 - 0 S P Stop Stopping
1 1 1 0 - 0 S P Stop Stopping
1 1 0 0 -> 1 - A1 S P Distance Positioning
1 1 1 0 -> 1 - A1 S P Distance Positioning
Distance = Parameter 44 + 45; relative distance with plus/minus sign. Positive distances are travelled in a clockwise direction.
Travel distance only if KP_H > 0
For further information, see page 33.
Stop control = If KP_H > 0; brake and stop in the current position on changeover to IN A = IN B = 1 + Coasting rh, lh.
If KP_H = 0; brake and stop on changeover to IN A = IN B = 1, run speed to 0.
S = Static
P = Parameter
F = Freeze
D = Dynamic
x = Arbitrary value