Owner's manual

Operating instructions
K3G200-BDA1-02
Translation of the original operating instructions
3.2 Nominal data
Motor M3G074-CF
Nominal voltage / VDC 24
Nominal voltage
range / VDC
16 .. 28
Type of data definition fa
State prelim.
Speed / min
-1
4060
Power input / W 185
Current draw / A 7.7
Max. back pressure / Pa 450
Min. ambient
temperature / °C
-25
Max. ambient
temperature / °C
+65
ml = max. load · me = max. efficiency · fa = running at free air
cs = customer specs · cu = customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive Yes
Specific ratio
*
1.00
*
Specific ratio = 1 + pfs / 100 000 Pa
Actual Request
2013
Request
2015
Overall efficiency ηes 45.2 28.9 31.9
Efficiency grade N 63.3 47 50
Power input Pe / kW 0.19
Air flow qv / m³/h 700
Pressure increase total psf / Pa 409
Speed n / min
-1
3975
Data established at point of optimum efficiency
3.4 Technical features
Mass 2.24 kg
Size 200 mm
Surface of rotor Coated in black
Material of impeller PA plastic
Housing material PA plastic
Material of support
bracket
PA plastic
Number of blades 7
Direction of air flow "V"
Direction of rotation Clockwise, seen on rotor
Type of protection IP 20
Insulation class "B"
Humidity class F0
Mounting position Any
Cooling bore / aperture Rotor-side
Operation mode S1
Motor bearing Ball bearing
Technical features - Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
- Over-temperature protected electronics
Motor protection Reverse polarity and locked-rotor
protection
Cable exit Lateral
Product conforming
to standard
EN 60335-1
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
3.7 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2 (industrial
environment)
EMC interference
emission
Acc. to EN 55022 (Class B, household
environment)
Item no. 50966-5-9970 · Revision 74201 · Release 2012-07-11 · Page 5 / 9