3.2 Nominal data
Motor M3G112-GA
Phase 1~
Nominal voltage / VAC 230
Nominal voltage
range / VAC
200 .. 277
Frequency / Hz 50/60
Type of data definition ml
State prelim.
Speed / min
-1
3000
Power input / W 1330
Power output / W 1100
Current draw / A 5.8
Rated torque / Ncm 350
Min. ambient temperature
/ °C
-25
Max. ambient temperature
/ °C
40
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Technical features
Mass 14.8 kg
Size 112 mm
Material of electronics
housing
Die-cast aluminium
Housing material Die-cast aluminium
Direction of rotation Counter-clockwise, seen on shaft
Type of protection IP 55
Insulation class "B"
Humidity class F3-1
Mounting position Any
Cooling bore / aperture Rotor-side
Operation mode S1
Motor bearing Ball bearing
Technical features - Output 10 VDC, max. 10 mA
- Output 20 VDC, max. 50 mA
- Output for slave 0-10 V
- Tach output
- Input for sensor 0-10 V or 4-20 mA
- Alarm relay
- Integrated PID controller
- Motor current limit
- PFC, active
- RS485 MODBUS RTU
- Soft start
- Control input 0-10 VDC / PWM
- Control interface with SELV potential
safely disconnected from the mains
- Over-temperature protected
electronics / motor
- Line undervoltage / phase failure
detection
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Electrical leads Via terminal box
Motor protection Thermal overload protector (TOP) wired
internally
Protection class I (if earth wire is connected by customer)
Product conforming
to standard
EN 61800-5-1; CE
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
Item no. 50876-5-9970 · Revision 74898 · Release 2013-08-20 · Page 5 / 10