Owner manual

Operating instructions
R3G133-RA01-03
Translation of the original operating instructions
3.2 Nominal data
Motor M3G045-AI
Phase 1~
Nominal voltage / VAC 230
Nominal voltage
range / VAC
200 .. 240
Frequency / Hz 50/60
Type of data definition ml
Speed / min
-1
3770
Power input / W 27
Current draw / A 0.27
Min. ambient temperature
/ °C
-25
Max. ambient
temperature
/ °C
60
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Technical features
Mass 0.5 kg
Size 133 mm
Surface of rotor Thick layer passivated
Material of electronics
housing
Die-cast aluminium
Material of impeller PA plastic
Number of blades 7
Direction of rotation Clockwise, seen on rotor
Type of protection IP 54
Insulation class "B"
Humidity class F3-1
Mounting position Any
Condensate discharge
holes
None, open rotor
Operation mode S1
Motor bearing Ball bearing
Technical features - Output 10 VDC, max. 1.1 mA
- Tach output
- Soft start
- Control input 0-10 VDC / PWM
- Over-temperature protected
electronics / motor
Touch current acc.
IEC 60990 (measuring
network Fig. 4, TN
system)
<= 3.5 mA
Motor protection Locked-rotor protection
Cable exit Variable
Protection class I (if protective earth is connected by
customer)
Product conforming
to standard
EN 60335-1; CE
Approval CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.4 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
mounting screws
8.8
You can obtain additional mounting data from the product drawing if
necessary.
3.5 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
+ 80 °C
Min. permissible
ambient motor temp.
(transp./storage)
- 40 °C
3.6 Electromagnetic compatibility
EMC interference
immunity
Acc. to EN 61000-6-2 (industrial
environment)
EMC harmonics Acc. to EN 61000-3-2/3
EMC interference
emission
Acc. to EN 61000-6-3 (household
environment)
Item no. 51159-5-9970 · Revision 80549 · Release 2014-04-07 · Page 5 / 10
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com