4.4 Connection screen
No. Conn. Designation Colour Function / assignment
2 L brown Power supply 230 VAC, 50-60 Hz, see type plate for voltage range
3 N blue Neutral conductor
1 PE green/
yellow
Protective earth
7 0-10 V PWM yellow Control input 0 - 10 V or PWM, electrically isolated
5 Tach white Tach output: Open Collector, 1 pulse per revolution, electrically isolated
6 10V red max. 1.1 mA, voltage output 10 V/1.1 mA, electrically isolated, not short-circuit-proof
4 GND blue GND - Connection for control interface
Item no. 51012-5-9970 · Revision 82598 · Release 2014-05-08 · Page 7 / 10