Product Data Sheet 2214 F/2TDHHO Product Data Sheet 2214 F/2TDHHO The engineer's choice
Product Data Sheet 2214 F/2TDHHO 2214 F/2TDHHO INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ......................................................................................
Product Data Sheet 2214 F/2TDHHO 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Width Height Depth Diameter Mass Housing material Impeller material 2.
Product Data Sheet 2214 F/2TDHHO Wire 1 2 3 4 Color red blue violet white Operation + UB - GND CONTR Tacho Wire size AWG 18 AWG 18 AWG 22 AWG 22 Insulation diameter 2,2 mm 2,2 mm 1,35 mm 1,35 mm The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery.
Product Data Sheet 2214 F/2TDHHO 3 Operating Data 3.
Product Data Sheet 2214 F/2TDHHO Schematics Input voltage divider: R1 = 47 kOhm R2 = 36 kOhm For protection: There is parallel to R2 a 5,1 V Z-Diode Speed control: By pulse-width modulation (PWM) 0 ... 100% with switching transistor in emitter circuit and collector resistor to 12 V Frequency = 2 kHz (1 - 10 kHz) Information to the curve PWM: 0% - <10% PWM: 0 1/min 10% PWM: 1.000 1/min (Fan on, comming from 0% PWM) 10% - 13% PWM: 1.000 1/min (corresponding to min.
Product Data Sheet 2214 F/2TDHHO Speed control: By analog voltage 0 - 10 V Information to the curve analog: 0 V - < 1,3 V: 0 1/min 1,3 V: 1.000 1/min (Fan on, comming from von 0 V) 1,3 V - 1,6 V: 1.000 1/min (corresponding to min. speed) 1,6 V - 9,4 V: linear increasing curve 9,4 V - 10 V: 5.000 1/min (corresponding to max.
Product Data Sheet 2214 F/2TDHHO 3.3 Electrical Interface - Output Tacho type Features Tacho operating voltage Tacho signal Low Tacho signal High Maximum sink current External resistor Tacho frequency Tacho isolated from motor Slew rate /2 (open collector) Note UBS US low US high Isink Values <= 36 V I sink: 2 mA <=0,4 V I source: 0 mA <=36 V <= 20 mA External resistor Ra from UBS to US required. All voltages measured to GND. (3 x n) / 60 250 Hz @ 5.
Product Data Sheet 2214 F/2TDHHO Voltage control *) 12A / 75V (Art.No.: 0451012.MRL) Fan turns on at UB > 14 V or < 40 V Fan turns off at UB < 13 V or > 42 V *) This fan has an undervoltage and overvoltage control circuit integrated which turns the motor off if the voltage is out of range. This fan has a startup delay of 2 seconds after applying supply voltage. Each startup (t3) hast two steps. Positioning of the rotor (ca. 3-4s) and the actual startup (~3s).
Product Data Sheet 2214 F/2TDHHO Running current @ 24 V (I = 0,5A/div ; t = 1ms/div) Locked rotor current @ 24 V (I = 0,5A/div ; t = 5s/div) 01/31/2019 page 10 of 14
Product Data Sheet 2214 F/2TDHHO 3.5 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions.
Product Data Sheet 2214 F/2TDHHO 3.6 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 5.000 1/min at free air flow U Contr.
Product Data Sheet 2214 F/2TDHHO 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H.