Datasheet
39
2016-01
Air performance measured according to: ISO 5801.
Installation category A, without contact protection.
Noise: Total sound power level L
W
A ISO 103002
measured on a hemisphere with a radius of 2 m.
Sound pressure level L
p
A measured at 1 m distance from
fan axis.
The values given are applicable only under the specified
measuring conditions and may differ depending on the
installation conditions.
In the event of deviation from the standard configuration,
the parameters must be checked after installation!
For detailed information see
http://www.ebmpapst.com/general conditions
– Possible special versions:
(See chapter DC fans - specials)
- Speed signal
- Go / NoGo alarm
- Moisture protection
- Degree of protection: IP 54 / IP 68
Max. 56 m
3
/h
– Material: Housing: GRP
1)
(PBT)
Impeller: GRP
1)
(PA)
– Direction of air flow: Exhaust over struts
– Direction of rotation: Clockwise,
looking towards rotor
– Connection: Via single wires AWG 22,
TR 64
– Highlights: Some models are suitable for
use at high ambient
temperatures up to 85 °C.
– Weight: 66 g
1) Fiberglass-reinforced plastic
Type m
3
/h cfm VDC VDC dB(A) Bel(A) / Watts rpm
-1
°C Hours Hours
612 NGLE 21 12.4 12 8...15 16 3.6 0.6 2 500 -20...+85 80 000 / 27 500 135 000 ➀
612 NLE 21 12.4 12 8...15 16 3.6 0.4 2 500 -20...+85 80 000 / 27 500 135 000 ➀
612 NGMLE 25 14.7 12 8...15 19 3.9 0.7 3 000 -20...+80 80 000 / 32 500 135 000 ➁
612 NMLE 25 14.7 12 8...15 19 3.9 0.4 3 000 -20...+85 80 000 / 27 500 135 000 ➁
612 NGME 35 20.6 12 8...15 28 4.6 1.2 4 100 -20...+75 80 000 / 35 000 135 000 ➂
612 NME 35 20.6 12 8...15 28 4.6 0.8 4 100 -20...+75 80 000 / 35 000 135 000 ➂
612 NN 42 24.7 12 8...15 35 5.0 1.5 5 100 -20...+70 70 000 / 35 000 117 500 ➃
612 NH 43 25.3 12 8...15 37 5.3 1.8 5 600 -20...+70 70 000 / 35 000 117 500 ➄
612 NHH-118 56 33.0 12 8...15 41 5.7 2.9 6 800 -20...+70 60 000 / 30 000 102 500 ➅
614 NGL 21 12.4 24 18...28 16 3.6 1.0 2 500 -20...+70 80 000 / 40 000 135 000 ➀
614 NL 21 12.4 24 18...28 16 3.6 0.8 2 500 -20...+70 80 000 / 40 000 135 000 ➀
614 NGML 25 14.7 24 18...28 19 3.9 1.2 3 000 -20...+70 80 000 / 40 000 135 000 ➁
614 NML 25 14.7 24 18...28 19 3.9 1.0 3 000 -20...+70 80 000 / 40 000 135 000 ➁
614 NGM 35 20.6 24 18...28 28 4.6 1.7 4 100 -20...+70 80 000 / 40 000 135 000 ➂
614 NM 35 20.6 24 18...28 28 4.6 1.3 4 100 -20...+70 80 000 / 40 000 135 000 ➂
614 NN 42 24.7 24 18...28 35 5.0 1.8 5 100 -20...+70 70 000 / 35 000 117 500 ➃
614 NH 43 25.3 24 18...26 37 5.3 2.1 5 600 -20...+70 70 000 / 35 000 117 500 ➄
614 NHH 56 33.0 24 18...26 41 5.7 2.9 6 850 -20...+70 60 000 / 30 000 102 500 ➅
614 NHH-119 56 33.0 24 18...28 41 5.7 2.9 6 850 -20...+70 60 000 / 30 000 102 500 ➅
618 NM 35 20.6 48 36...56 28 4.6 1.9 4 100 -20...+70 80 000 / 40 000 135 000 ➂
618 NN 42 24.7 48 36...56 35 5.0 2.1 5 100 -20...+65 70 000 / 40 000 117 500 ➃
Nominal voltage
Air flow
Air flow
Voltage range
Sound pressure level
Sound power level
Sintec sleeve bearings
Ball bearings
Power consumption
Nominal speed
Temperature range
Service life L
10
(40 °C)
ebm-papst standard
Service life L
10
(T
max
)
ebm-papst standard
Life expectancy L
10IPC
(40 °C) see page 17
Curve
InformationDC axial fansDC fans - specialsACmaxx / EC fansAC axial fansAccessoriesRepresentatives DC centrifugal fansAC centrifugal fans
Tin-plated
Finger guards
from p. 242
DC axial fans
60 x 25 mm
Series 600 N
Nominal data