Product Data Sheet 6314/2HP Product Data Sheet 6314/2HP The engineer's choice
Product Data Sheet 6314/2HP 6314/2HP INDEX 1 General ...................................................................................................................................................................... 3 2 Mechanics ................................................................................................................................................................. 3 2.1 2.2 3 Operating Data ..................................................................................
Product Data Sheet 6314/2HP 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Depth Diameter Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 2.
Product Data Sheet 6314/2HP The auxilliaries shown on the schematic diagram (which are required for the intended use) are not part of our delivery.
Product Data Sheet 6314/2HP 3 Operating Data 3.
Product Data Sheet 6314/2HP 3.2 Electrical Operating Data Measurement conditions: ∆p = 0: I: Name PWM 0001 Features Voltage range Nominal voltage Power consumption Tolerance Current consumption Tolerance Speed Tolerance Normal air density = 1,2 kg/m3; Temperature 23°C +/- 3°C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. corresp.
Product Data Sheet 6314/2HP 3.3 Electrical Interface - Output Tacho type Features Tacho operating voltage Tacho signal Low Tacho signal High Maximum sink current External resistor Tacho frequency Tacho isolated from motor Slew rate /2 (open collector) Note UBS US low US high Isink Values <= 32,0 V I sink: 2 mA <= 0,4 V I source: 0 mA <=32,0 V <= 20 mA External resistor Ra from UBS to US required. All voltages measured to GND.
Product Data Sheet 6314/2HP 3.4 Electrical Features Electronic function Reversed polarity protection Max. residual current at UN Locked rotor protection Locked rotor current at UN Clock signal at locked rotor 3.5 Speed-Controlled Rectifying diode IF <= 5 mA Auto restart Iblock approx. 850 mA t3 / t4 typical: 0,5 s / 7,0 s Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801.
Product Data Sheet 6314/2HP 3.6 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 5.
Product Data Sheet 6314/2HP 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H.