Product Data Sheet 7214 N/19 Product Data Sheet 7214 N/19 The engineer's choice
Product Data Sheet 7214 N/19 7214 N/19 INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ..............................................................................................
Product Data Sheet 7214 N/19 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Fan Counterclockwise Air outlet over struts Ball bearing Any Depth Diameter Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 2.
Product Data Sheet 7214 N/19 3 Operating Data 3.1 Electrical Operating Data Measurement conditions: ∆p = 0: I: Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. corresp. to free air flow (see chapter aerodynamics) corresp. to arithm.
Product Data Sheet 7214 N/19 3.2 Electrical Interface - Output Alarm type /19 (low = ok, open collector inverse) Features Note Alarm operating voltage UBA Alarm signal Low Alarm signal High Maximum sink current UA low UA high Isink External resistor Alarm start-up delay time t6 Tolerance Alarm delay time Values Max.: 60,0 V I sink: 10 mA I source: <= 0,8 V 60,0 V 10 mA External resistor Ra from UBA to UA required. All voltage measured to GND.
Product Data Sheet 7214 N/19 Alarm delay time t2 during the start up and after alarm reset. While operation ist t2 = 0 s. 3.3 Electrical Features Electronic function Reversed polarity protection Max. residual current at UN Locked rotor protection Locked rotor current at UN Clock signal at locked rotor None Rectifying diode IF < 10 mA Auto restart Iblock approx. 2.
Product Data Sheet 7214 N/19 3.4 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions.
Product Data Sheet 7214 N/19 3.5 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 3.
Product Data Sheet 7214 N/19 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H.