Product Data Sheet AC 4300 HR The engineer's choice
Product Data Sheet AC 4300 HR AC 4300 HR INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ............................................................................................
Product Data Sheet AC 4300 HR 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Width Height Depth Diameter Mass Housing material Impeller material 2.
Product Data Sheet AC 4300 HR 3 Operating Data 3.1 Electrical Interface - Input External voltage supply for input and output signals must be SELV conform. Control input None Features 3.
Product Data Sheet AC 4300 HR 3.4 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions.
Product Data Sheet AC 4300 HR 2/28/2019 page 6 of 10
Product Data Sheet AC 4300 HR 3.5 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a) Operation condition: 3.
Product Data Sheet AC 4300 HR 4.2 Climatic Requirements IP-protection type (certified) Humidity requirements Salt fog requirements IP 20 **) humid heat, constant; according to DIN EN 60068-278, 14 days None Permitted application area: The product is intended for use in sheltered rooms with controlled temperature and controlled humidity. Directly exposure to water must be avoided. Pollution degree 1 (according DIN EN 60664-1) There is either no pollution or it occurs only dry, non-conductive pollution.
Product Data Sheet AC 4300 HR 5 Safety 5.1 Electrical Safety A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock, ingress of solid foreign objects and water has to be done in conjuction with the appliance. Test voltage HV type test Unit test voltage Time type test HV Insulation resistance Protection class 5.