Product Data Sheet AC 6200 NMU The engineer's choice
Product Data Sheet AC 6200 NMU AC 6200 NMU INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ..........................................................................................
Product Data Sheet AC 6200 NMU 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Width Height Depth Diameter Mass Housing material Impeller material Max. torque when mounted across both mounting flanges Screw size 2.
Product Data Sheet AC 6200 NMU 3 Operating Data 3.1 Electrical Interface - Input External voltage supply for input and output signals must be SELV conform. Control input None Features 3.
Product Data Sheet AC 6200 NMU 3.4 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions.
Product Data Sheet AC 6200 NMU 2/28/2019 page 6 of 10
Product Data Sheet AC 6200 NMU 3.5 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a) Operation condition: 2.
Product Data Sheet AC 6200 NMU 4.2 Climatic Requirements IP-protection type (certified) Humidity requirements IP 65 (for fan only, not for connector if applicable) **) humid temperature, cyclic; according to DIN EN 60068-2-38, 10 cycle and condensation water check; according to DIN EN ISO 6270-2, 14 days Salt fog requirements None Permitted application area: The product is for the use in partial sheltered rooms or open, roofed areas.
Product Data Sheet AC 6200 NMU 5 Safety 5.1 Electrical Safety A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock, ingress of solid foreign objects and water has to be done in conjuction with the appliance. Test voltage HV type test Unit test voltage Time type test HV Insulation resistance Protection class 5.