Product Data Sheet AC 8300/19H The engineer's choice
Product Data Sheet AC 8300/19H AC 8300/19H INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ..........................................................................................
Product Data Sheet AC 8300/19H 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Width Height Depth Diameter Mass Housing material Impeller material 2.
Product Data Sheet AC 8300/19H Wire 1 2 3 4 Color black black blue white 3 Operating Data 3.1 Electrical Interface - Input Operation L1 L2 - GND Alarm Alarm External voltage supply for input and output signals must be SELV conform.
Product Data Sheet AC 8300/19H 3.2 Electrical Operating Data Features Voltage range Tolerance Nominal voltage Frequency Power consumption Tolerance Current consumption Tolerance Speed Condition Symbol U Values UN f ∆p = 0 P ∆p = 0 IRMS ∆p = 0 265 V 100 V 115 230 V 50 Hz / 60 Hz 7,5 W +- 20 % 130 mA 115 mA 58 mA 53 mA +- 20 % +- 25 % +- 20 % 5.000 1/min +- 10 % +- 25 % n Tolerance 3.
Product Data Sheet AC 8300/19H Alarm type /19 (low = ok, open collector inverse) Features Alarm operating voltage Alarm signal Low Note Values I sink: 2 mA Alarm signal High I source: <= 0,4 V 48 V Min.: 0 V Maximum sink current Alarm start-up delay time Alarm trip speed limit <= 20 mA < 15 s 1.500 1/min +- 100 1/min Tolerance Alarm at sense failure Alarm latch Alarm isolated from motor Max.
Product Data Sheet AC 8300/19H 3.
Product Data Sheet AC 8300/19H 3.5 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions.
Product Data Sheet AC 8300/19H 2/28/2019 page 9 of 12
Product Data Sheet AC 8300/19H 3.6 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a) Operation condition: 5.
Product Data Sheet AC 8300/19H 5 Safety 5.1 Electrical Safety A verification of thermal conditions (normal and abnormal operation) as well as the protection against electric shock, ingress of solid foreign objects and water has to be done in conjuction with the appliance. Test voltage HV type test Unit test voltage Time type test HV Insulation resistance Protection class 5.