Datasheet
AC centrifugal module - RadiCal
backward-curved, single-intake
with housing
K2E133-RA03-01
Curves: Air performance 50 Hz
Druck p f s[Pa]für Rho=1,2kg/m^3
qv[m^3/h]
2202102001901801701601501401301201101009080706050403020100
qv[cfm]
120100806040200
p f s[Pa]
210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
pfs _E[IN H2O]
0,8
0,75
0,7
0,65
0,6
0,55
0,5
0,45
0,4
0,35
0,3
0,25
0,2
0,15
0,1
0,05
0
p f s[Pa]
1
2
3
4
Measurement: LU-131804-1
Air performance measured according to ISO
5801 installation category A. For detailed
information on the measurement setup,
contact ebm-papst. Intake sound level:
Sound power level according to ISO 13347 /
sound pressure level measured at 1 m
distance from fan axis. The values given are
valid under the specified measuring
conditions and may vary due to conditions of
installation. For deviations from the standard
configuration, the parameters have to be
checked on the installed unit.
Measured values
1
2
3
4
U
V
230
230
230
230
f
Hz
50
50
50
50
n
min
-1
2750
2725
2700
2730
P
e
W
25
25
26
24
I
A
0.11
0.11
0.12
0.11
LpA
in
dB(A)
49
47
44
48
LwA
in
dB(A)
58
56
53
57
q
V
m
3
/h
195
165
125
75
p
fs
Pa
0
60
120
160
q
V
cfm
115
95
75
45
p
fs
inH2O
0.00
0.24
0.48
0.64
U = Power supply · f = Frequency · n = Speed (rpm) · P
e
= Power consumption · I = Current draw · LpA
in
= Sound pressure level intake side · LwA
in
= Sound power level intake side
q
V
= Air flow · p
fs
= Pressure increase
Item no. 11454-5-9980 · ENU · Change 89188 · Approved 2016-08-25 · Page 4 / 5
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com