Datasheet
AC centrifugal module - RadiCal
®
backward curved, single inlet
with housing
K2E225-RA92-01
ebm-papst Mulfingen GmbH & Co. KG
Bachmühle 2 · D-74673 Mulfingen
Phone +49 7938 81-0
Fax +49 7938 81-110
info1@de.ebmpapst.com
www.ebmpapst.com
Limited partnership · Headquarters Mulfingen
County court Stuttgart · HRA 590344
General partner Elektrobau Mulfingen GmbH · Headquarters Mulfingen
County court Stuttgart · HRB 590142
Nominal data
Type K2E225-RA92-01
Motor M2E068-DF
Phase 1~ 1~ 1~
Nominal voltage VAC 230 230 230
Frequency Hz 50 60 60
Type of data definition ml ml ml
Valid for approval / standard CE CE UL 2111
Speed min
-1
2500 2600 2600
Power input W 155 210 225
Current draw A 0.68 0.92 0.95
Motor capacitor µF 3.5 3.5 3.5
Capacitor voltage VDB 450 450 450
Capacitor standard UL
Min. back pressure Pa 0 0 0
Min. ambient temperature °C -25 -25 -25
Max. ambient temperature °C 70 65 65
Starting current A 1.25 1.2
ml = Max. load · me = Max. efficiency · fa = Running at free air · cs = Customer specs · cu = Customer unit
Subject to alterations
Data according to ErP directive
Installation category A
Efficiency category Static
Variable speed drive No
Specific ratio
*
1.00
*
Specific ratio = 1 + p
fs
/ 100 000 Pa
Actual Request 2013 Request 2015
Overall efficiency η
es
% 42.5 38.5 42.5
Efficiency grade N 62 58 62
Power input P
e
kW 0.14
Air flow q
v
m³/h 705
Pressure increase p
fs
Pa 320
Speed n min
-1
2560
Data definition with optimum efficiency. LU-127147
The ErP data is determined using a motor-impeller combination in a standardised measurement configuration.
Item no. 11021-5-9980 · Revision 82063 · Release 2014-05-08 · Page 1 / 6
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com