Product Data Sheet REF100-11/12 Product Data Sheet REF100-11/12 The engineer's choice
Product Data Sheet REF100-11/12 REF100-11/12 INDEX 1 General ............................................................................................................................................................... 3 2 Mechanics .......................................................................................................................................................... 3 2.1 2.2 3 Operating Data ........................................................................................
Product Data Sheet REF100-11/12 1 General Fan type Rotating direction looking at rotor Airflow direction Bearing system Mounting position - shaft 2 Mechanics 2.1 General Depth Diameter Mass Housing material Impeller material 2.
Product Data Sheet REF100-11/12 3 Operating Data 3.1 Electrical Operating Data Measurement conditions: ∆p = 0: I: Features Voltage range Nominal voltage Power consumption Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; Motor axis horizontal; warm-up time before measuring 5 minutes (unless otherwise specified). In the intake and outlet area should not be any solid obstruction within 0,5 m. corresp. to free air flow (see chapter aerodynamics) corresp. to arithm.
Product Data Sheet REF100-11/12 02/01/2019 page 5 of 10
Product Data Sheet REF100-11/12 3.3 Aerodynamics Measurement conditions: Measured with a double chamber intake rig acc. to DIN EN ISO 5801. Normal air density = 1,2 kg/m3; Temperature 23°C +/ - 3°C; In the intake and outlet area should not be any solid obstruction within 0,5 m. Motor shaft horizontal. The information is only valid under the specified test conditions and may be changed by the installation conditions.
Product Data Sheet REF100-11/12 3.4 Sound Data Measurement conditions: Sound pressure level: 1 meter distance between microphone and the air intake. Sound power level: Acc. to DIN 45635 part 38 (ISO 10302) Measured in a semianchoic chamber with a background noise level of Lp(A) < 5 dB(A) For further measurement conditions see chapter aerodynamics. a.) Operation condition: 5.
Product Data Sheet REF100-11/12 Kind According Ceck accuracy / Limit Result Electrostatic Discharge Immunity Test DIN EN 61000-4-2:2001-12 Contact Discharge +/- 4 kV; Air Discharge +/- 8 kV A: The monitored function operates as designed during and after exposure to a disturbance.
Product Data Sheet REF100-11/12 5 Safety 5.1 Electrical Safety Dielectric strength DIN EN 60950 (VDE 0805) and DIN EN 60335 (VDE 0700) A.) Type test Measuring conditions: After 48h of storage at 95% R.H. and 25°C. No arcing or breakdown is allowed! All connections together to ground. B.) Routine test Measuring conditions: At indoor climate. No arcing or breakdown is allowed! All connections together to ground. Isolation resistance Measuring conditions: After 48h of storage at 95% R.H.